Fire Alarm Control Panel with Built-in DACT and Remote-site Upload/download Capability
Manufacturer
ETC
Datasheet
Flex 405
Fire Alarm Control Panel with built-in DACT
and remote-site upload/download capability
Flex 405 CS-2405 02/15/05
host fire alarm panel (requires normally-open dry contacts to trigger five
channels). Selectable transmission formats allow the Flex 405 to communi-
cate to virtually all central stations.
Remote-Site Upload/Download
The Flex 405 may be downloaded or uploaded without affecting the system
fire protection. Download system programming, and upload key system
information such as: current system status, history and walk test files;
zone, AC line, NAC 1 and NAC 2, resettable power and battery voltages;
and system programming. Upload or download within one minute without
affecting normal fire panel functions. The upload/download function also
features multiple security techniques. The Flex 405 requires the PK-CD
programming kit, which works with most Hayes-compatible modems
(consult factory for listing).
station. The Flex 405 may be used
in a variety of cost-effective applica-
tions, including: local fire alarm
control panel (communicator dis-
abled), fire alarm control panel/
communicator, stand-alone sprin-
kler supervisory communicator, or
slave communicator to a UL-Listed
Description
The Gamewell Flex 405 is a 24-volt,
five-zone Fire Alarm Control Panel
FACP) with built-in communicator
and remote-site upload/download
capability. The integral communica-
tor transmits event information
(alarms, troubles, supervisories,
faults, etc.) to a UL-Listed central
PK-CD
PK-CD
PK-CD
PK-CD
Page 1 of 4
Features
• Five programmable Initiating Device Circuits
• Two built-in, Class A or B (Style Z or Y)
• 3.0 amps of notification appliance power,
• Two built-in Form-C Alarm and Trouble relays.
• Supervisory and communication fail outputs.
• Dual-line rotary- or Touch-Tone®-dial DACT
• 24-Volt operation.
• Built-in voltmeter measures: zone voltage;
• Surface Mount Technology (SMT).
• Fully programmable via built-in keypad (no
• Complies with NFPA 72 (Local, Central
• Reporting formats include:
• Integral battery charger for up to 60 hours of
• Fuseless, power-limited technology meets UL
• Programmable alarm presignal timer, alarm
• Single-person walk test. Fire drill function.
• Zone disable capability (software).
• 32-Event history buffer with time-and-date
• Extensive built-in transient protection.
• Electronics and operational controls fully
• Optional: contact-by-zone module, remote
Listings
• UL Listed.
• CSFM approved: file 7165-1288:179.
• MEA approved: file 366-04-E.
(zones). Each zone may be programmed for:
two-wire smoke detectors, normally open
contact devices (pull stations, heat
detectors), four-wire smoke detectors,
waterflow operation, supervisory operation,
auto-reset supervisory operation.
Notification Appliance Circuits (NACs). NACs
may be programmed: silenceable, non-
silenceable (a strobe circuit can keep flashing
after the panel is silenced), auto-silence
(program 5 to 30 minutes), silence inhibit (60
seconds), coding (march time, temporal,
California).
expandable to 5.0 amps (meets the critical
power requirements for ADA and UL-1971
devices).
interfaces to public telephone network
(leased phone lines are not required).
primary AC line voltage; battery voltage;
NAC(s) voltage; resettable 24-volt power.
costly external programmers necessary).
Station and Remote Station [DACT only – not
polarity reversal] Fire Alarm Systems).
3+1, 4+1, 4+2 Standard + Expanded;
4+1, 4+2, Ademco Express.
standby power.
power-limiting requirements.
verification timer, and optional trouble
reminder.
stamp. Accurate real-time clock/calendar.
enclosed in a lockable cabinet capable of
housing up to 7 AH batteries.
annunciator, printer interface for on- or off-
line printing.
Listings and approvals below apply to the
basic Flex 405 panel. In some cases, certain
modules may not be listed by certain approval
agencies, or listing may be in process.
Consult factory for latest listing status.