ATA5275-PGQ ATMEL Corporation, ATA5275-PGQ Datasheet - Page 9

no-image

ATA5275-PGQ

Manufacturer Part Number
ATA5275-PGQ
Description
125 kHz Transmitter IC FOR TPM
Manufacturer
ATMEL Corporation
Datasheet
3.7.1
3.7.2
4739C–AUTO–02/05
Circuit Protection Cases
Error Diagnosis
The circuit protection is activated in normal mode. It is switched off in standby mode. In case a
protection switch-off occurs the half-bridge is set in tri-state mode.
For all cases, there is a filter implemented to debounce half-bridge switch-off for a time of T
(typically 20 µs). This debounce filter is activated in case the half-bridge is activated. Otherwise
it is RESET.
These are the following circuit protection cases:
During the transmission the diagnosis function of the IC supervises the antenna current and fre-
quency and the half-driver bridge supply voltage. If any error is detected at the end of the
transmission cycle the error indication is set (as in circuit protection case).
There are the following diagnosis cases:
1. Load dump protection: In case the voltage at DVCC exceeds a voltage VBAT
2. Overcurrent protection: In case the current through the high side DMOS of the half-
3. Overtemperature protection: In case the junction temperature exceeds a value of TSD
1. Under-voltage detection: Monitors if DVCC is below VBAT
2. Antenna frequency error: Diagnosis if the oscillation frequency during transmission is
3. Antenna peak current error: Diagnosis if the peak current is greater than the adjusted
cally 31 V).
bridge exceeds a value of IOCH or the current through the low side DMOS of the half-
bridge exceeds a value of IOCL (typically 2 A).
(typically 165°C).
outside the typical tracking range 90 kHz to 160 kHz.
IA
PEAK
+ 15% typically.
ATA5275 [Preliminary]
UV
(typically 6.5 V).
LD
(typi-
DEB
9