ATA6026 ATMEL Corporation, ATA6026 Datasheet - Page 21

no-image

ATA6026

Manufacturer Part Number
ATA6026
Description
H-bridge Motor Driver
Manufacturer
ATMEL Corporation
Datasheet
7. Electrical Characteristics (Continued)
All parameters given are valid for 7V VBAT 40V and for –40°C
Conditions: SEM = HIGH (single-ended mode of SCI).
4865C–AUTO–01/06
* Type: A = 100% tested, B = 100% correlation tested, C = Characterized on samples, D = Design parameter
Notes:
2.10
No.
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
2.9
3.1
3.2
3.3
3.4
2
3
1. EN, DIR, PWM = HIGH
2. Internal band-gap voltage is valid for VBAT > 3V (not testable)
3. Valid for –40°C to +90°C
4. R
5. Tested during qualification only
6. For timing, see the formula in
7. External parasitic capacitive load together with pull-up resistor at RX defines the time t
8. If single-ended mode is used (SEM = HIGH): DATA is not used and VBAT / 2 instead of DATA is the internal reference for
9. Maximum voltage difference arises during slope, see
10. Parameters 4.16 to 4.19 are based on transmit voltage slopes at DATA and /DATA of 4V/µs ±50%
Parameters
2.2V-5V Regulator
Regulated output voltage
Regulated output voltage
Line regulation
Load regulation
Output current limitation
Output current limitation
Output current VREG
ESR value of used
blocking capacitor
Blocking capacitor at VCC
Current gain of external
NPN
Reset and Watchdog
VCC threshold voltage
level for /RESET
VCC threshold voltage
level for /RESET
Hysteresis of /RESET
level
Length of pulse at
/RESET pin
and R
parameters 4.10 and 4.11
SHUNT
CWD
= 1
, tolerances of these elements have to be added to the given tolerances in the above table
(4)
(4)
Test Conditions
V
I
6V < V
I
I
V
I
V
6V < V
V
V
Combination with HF
capacitor of 100 nF
/RESET pulse triggered
by watchdog,
C
R
load
load
load
load
VBAT
VBAT
VBAT
VREG
VBAT
CWD
CWD
= 0 mA to 100 mA
= 0 mA to 50 mA
= 0 mA to 100 mA
= 0 mA to 100 mA
“Reset and Watchdog Management” on page
> 9V
> 9V
> 9V
= 9V
= 1 nF
= 56 k
= 5V, V
VBAT
VBAT
9V
9V
VCC
= 0V,
Pin
Figure 7-1 on page 30
ambient
HYS
Symbol
loadreg
V
V
linereg
VCC
VCC
I
R
C
tHRESH
tHRESL
125°C unless stated otherwise.
I
I
VREG
t
BN
OS1
OS2
RES
ESR
VCC
RESth
1
2
8. All times depend on external elements C
4.85
2.58
Min
100
4.5
0.3
4.2
3.8
50
40
25
3
0.4
RxH
Typ
(5)
Max
5.15
4.15
2.96
100
400
400
100
5.5
4.6
20
3
ATA6026
Unit
mV
mV
mA
mA
mA
ms
µF
V
V
V
V
V
Type*
CWD
21