ADAM-4571S ETC, ADAM-4571S Datasheet

no-image

ADAM-4571S

Manufacturer Part Number
ADAM-4571S
Description
(ADAM-4570 / ADAM-4571) User Manual
Manufacturer
ETC
Datasheet
ADAM-4570/4570L/4570S/
ADAM-4571/4571L/4571S/
EDG-4504
1/2/4 Port Ethernet to
RS-232/422/485 Data Gateway
User’s Manual
www.DataSheet4U.com

Related parts for ADAM-4571S

ADAM-4571S Summary of contents

Page 1

... ADAM-4570/4570L/4570S/ ADAM-4571/4571L/4571S/ EDG-4504 1/2/4 Port Ethernet to RS-232/422/485 Data Gateway User’s Manual ...

Page 2

... CE Notification The ADAM-4570/ADAM-4570L/ADAM-4570S/ADAM-4571/ADAM- 4571L/ADAM-4571S/EDG-4504 has passed the CE test for environ- mental specifications. Test conditions for passing included the equipment being operated within an industrial enclosure. In order to protect the ADAM-4570/ADAM-4570L/ADAM-4570S/ADAM-4571/ ...

Page 3

Advantech Customer Services Each and every Advantech product is built to the most exacting specifications to ensure reliable performance in the unusual and demanding conditions typical of industrial environments. Whether your new Advantech equipment is destined for the laboratory or ...

Page 4

... Collect all the information about the problem encountered (e.g. type of PC, CPU speed, Advantech products used, other hardware and software used etc.). Note anything abnormal and list any on-screen messages you get when the problem occurs. 2. Call your dealer and describe the problem. Please have your manual, product, and any helpful information readily available ...

Page 5

Write the RMA number visibly on the outside of the package and ship it prepaid to your dealer. www.DataSheet4U.com ...

Page 6

... Understanding the Advantech EDG Series ................. 9 2.1.1 Network Architecture ....................................................... 9 2.1.2 Secure Communication .................................................. 11 2.1.2.1 Data Integrity ............................................................ 11 2.1.2.2 Access Control and Local Password Configuration12 2.1.3 Top / Front / Rear View .................................................. 13 2.1.3.1 ADAM-4570/4570L/4570S ....................................... 13 2.1.3.2 ADAM-4571/4571L/4571S ....................................... 15 2.1.3.3 EDG-4504 ................................................................ 17 2.1.4 Stickers ......................................................................... 19 www.DataSheet4U.com 2.2 Connecting the Hardware ........................................... 19 2.2.1 Choosing a Location ...................................................... 19 2.2.1.1 ADAM-4570/4570L/4570S/4571/4571L/4571S ....... 19 2.2.1.2 EDG-4504 ................................................................ 23 2.2.2 Network Connection ....................................................... 24 2.2.3 Power Connection .......................................................... 24 2.2.4 Serial Connection ........................................................... 26 2.2.4.1 ADAM-4570/4570L/4570S/4571/4571L/4571S ....... 26 2.2.4.2 Contents EDG-4504 ............................................................... 28 ...

Page 7

Chapter 3: Installation and Configuration .. 29 3.1 Driver and Utility Installation ....................................... 30 3.2 Configuring the EDG Series — The Configuration Utility ............................................. 31 3.2.1 Search for Specific EDG Series ..................................... 32 3.2.2 System Configuration ..................................................... 34 3.2.3 Network ...

Page 8

... Figure 2-20 Power Connection for EDG-4504 ............................................ 25 Figure 2-21 Serial Connection for ADAM-4570/4570L/4570S/4571/ 4571L/4571S. ........................................................................... 26 Figure 2-22 Serial Connection for EDG-4504 ............................................. 28 Figure 3-1 Configuration Utility ................................................................. 31 Figure 3-2 Locate all EDG Series .............................................................. 32 Figure 3-3 Locatet he desired group of ADAM-4570S/4571S ................. 33 Figure 3-4 Locate specific ADAM-4570S/4571S ..................................... 33 Figure 3-5 System Setting Window .......................................................... 34 Figure 3-6 Network Configuration Window ............................................. 37 Figures ...

Page 9

Figure 3-7 Port Configuration Window ..................................................... 38 Figure 3-8 Security configuration ............................................................. 40 Figure 3-9 Status messages .................................................................... 41 Figure 3-10 Unused ports ........................................................................... 43 Figure 3-11 Assign COM port to EDG Series .............................................. 44 Figure 3-12 Warning window ...................................................................... ...

Page 10

... Table 2-1 ADAM-4570/4570L/4570S LED Definition ............................... 13 Table 2-2 ADAM-4571/4571L/4571S LED Definition ............................... 15 Table 2-3 EDG-4504 LED Definition ......................................................... 17 www.DataSheet4U.com Tables ...

Page 11

Overview ...

Page 12

... Internet world. The ADAM-4570/ADAM-4571/EDG-4504 provides multiple RS- 232/422/485 serial ports easily individually configured for your needs and ADAM-4570L/4571L provides RS-232 serial ports. ADAM-4570S/4571S provides security mechanism to protect sensitive data from being altered or accessed by unauthorized users in the RS-422/485 networks. ...

Page 13

In addition, The EDG series comes with a Windows-based con- figuration and port-mapping utility. The configuration tool can auto-detect all EDG series on the local network. It also lets you adjust all settings easily. The port mapping utility helps you ...

Page 14

... Port: 1/2/4 independent RS-232/422/485 ports ADAM-4570: Two RS-232/422/485 ports ADAM-4570L: Two RS-232 ports ADAM-4570S: Two RS-422/485 ports ADAM-4571: One RS-232/422/485 port ADAM-4571L: One RS-232 port ADAM-4571S: One RS-422/485 port EDG-4504: Four RS-232/422/485 ports • Connector: Network: RJ-45 Serial: RJ-48 (RJ-48 to DB-9 cable provided) for ADAM- 4570/4570L/4570S/4571/4571S/EDG-4504 and DB-9 for www ...

Page 15

... Easy-to-manage port mapping utility • Driver Supported: Windows 95/98/NT/2000/ME/XP driver • Power Requirements: unregulated Vdc with surge protection • Power Consumption: ADAM-4570: 4W ADAM-4571: 3.5W ADAM-4570L/4571L: 1.5W EDG-4504: 4.5W • Placement: DIN-rail, panel mounting, piggyback stack (ADAM-4570/4570L/4570S/4571/4571L/4571S) DIN-rail, panel mounting (EDG-4504) • Operating Temperature 60° C www.DataSheet4U.com • ...

Page 16

... Package Checklist • User’s Manual • CD-ROM for utility and manual • 1/2/4 RJ-48 to DB-9 serial cables (except ADAM-4571L) • One RS-232 loopback DB-9 tester • Five stickers • NYLON DIN-rail Mounting Adapter • SECC Panel Mounting Bracket www.DataSheet4U.com 6 Advantech EDG series User’s Manual ...

Page 17

Getting Started ...

Page 18

In this chapter, you will be given an overview of the EDG series hardware installation procedures. As mentioned in the previous chapter, the EDG series comes ready for all network connec- tions, including Ethernet, and RS-232/422/485 port connections. We begin ...

Page 19

Understanding the Advantech EDG Series The EDG series is an advanced data gateway unit. It extends traditional COM ports with access over a TCP/IP net- work. Through networking, you can control and monitor re- mote serial ...

Page 20

... The following illustration shows the network architecture as be- low: www.DataSheet4U.com 10 Advantech EDG series User’s Manual Eth ernet ADAM RS-23 2/4 22/4 85 Port 1 Port 2 +Vs GND Figure 2-2 Network Architecture(1) Figure 2-3 Network Architecture(2) ...

Page 21

... Secure Communication Advanced multiple security features protect the system and make data more private and secure. The ADAM-4570S/4571S guards your network and data by multiple security protections: T-DES (Triple Data Encryption Standard, which is specified in FIPS PUB 46-2 and American National Standard X9.25) strong en- cryption, PKCS#5 (Password-based Cryptographic Standard #5), and IP address authorization ...

Page 22

... Configuration IP access control can block users from unauthorized hosts; it only allows 32 users to access at one time. In addition, the ADAM-4570S/4571S protects all configuration settings from being changed inadvertently. When this option is enabled, only the corresponding PC can configure the module. The multiple security mechanisms work to prevent unauthorized access to your RS-422/485 networks ...

Page 23

... Top / Front / Rear View 2.1.3.1 ADAM-4570/4570L/4570S There are five network status LEDs located on the top panel of ADAM-4570/4570L/4570S, each with its own specific func- tion. LED Status/Power Speed/Link Tx/Rx (Ethernet) www.DataSheet4U.com Tx/Rx (port1) Tx/Rx (port2) Table 2-1 ADAM-4570/4570L/4570S LED Definition Color Status Description ON Heartbeat (1 time/sec) Red OFF ...

Page 24

... Figure 2-4 ADAM-4570/4570L/4570S—Top Panel Figure 2-5 ADAM-4570/4570L/4570S—Front Panel www.DataSheet4U.com Figure 2-6 ADAM-4570/4570L/4570S—Back Panel 14 Advantech EDG series User’s Manual ...

Page 25

... ADAM-4571/4571L/4571S There are four LEDs located on the top panel of ADAM-4571/ 4571L/4571S, each with its own specific function. LED Status/Power Speed/Link Tx/Rx (Ethernet) Tx/Rx (port1) www.DataSheet4U.com Table 2-2 ADAM-4571/4571L/4571S LED Definition Color Status Description ON Heartbeat (1 time/sec) Red OFF Not working ON Power ON Green OFF Power OFF ...

Page 26

... Figure 2-7 ADAM-4571/4571L/4571S—Top Panel Figure 2-8 ADAM-4571/4571L/4571S—Front Panel www.DataSheet4U.com Figure 2-9 ADAM-4571/4571L/4571S—Back Panel 16 Advantech EDG series User’s Manual P o rt1 ...

Page 27

EDG-4504 There are 13 LEDs located on the top panel of EDG-4504, each with its own specific function. LED Status 10M 100M TX (Ethernet) RX (Ethernet) TX (port N) N=1~4 www.DataSheet4U.com RX (port N) N=1~4 Status ON OFF ON ...

Page 28

Advantech EDG series User’s Manual Figure 2-10 EDG-4504—Top Panel Figure 2-11 EDG-4504—Front Panel Figure 2-12 EDG-4504—Front Panel ...

Page 29

... Stickers If you forgot the IP addresses of specific EDG Series or where the host PC is mapped to the ADAM-4570 port, we have pro- vided five stickers for you to note the IP addresses and place in a secure location. For example, 172.20.20.5: The IP address of specific ADAM-4570 160.59.20.89: The IP address of the specific host PC mapped to this port ...

Page 30

... Panel Mounting The ADAM-4570/4570L/4570S/4571/4571L/4571S can be attached to a wall using the included metal brackets. Each bracket comes with four screws; first attach the brackets to the bottom of the ADAM-4570/4570L/4570S/4571/4571L/4571S. Next, screw each bracket to a wall. www.DataSheet4U.com 20 Advantech EDG series User’s Manual Figure 2-13 Panel Mounting ...

Page 31

... DIN Rail Mounting You can mount the ADAM-4570/4570L/4570S/4571/4571L/ 4571S on a standard DIN Rail. First, using two screws, attach the metal plate to the DIN Rail bracket. Because the screw heads are beveled, the tops of the screws will be flush with the metal plate. Din Rail Mounting Brackets—Orientation of Metal Plates You can now screw the metal plate with the DIN rail bracket assembly to the bottom of the server is a more convenient way ...

Page 32

... Piggyback Stack ADAM-4570/4570L/4570S/4571/4571L/4571S can be stacked as seen in the figure below. www.DataSheet4U.com 22 Advantech EDG series User’s Manual Figure2-15 Piggyback Stack ...

Page 33

EDG-4504 www.DataSheet4U.com Figure 2-16 Din Rail Mounting Figure 2-17 Panel Mounting Chapter 2 Getting Started 23 ...

Page 34

... There are two ways to use the 10/100Base-T Ethernet connec- tor located on the EDG Series: 1. For Local Area Network (LAN) applications using the EDG Series, you will simply plug one end of your Ethernetcable into the 10/100Base-T connector, and the other end into the hub connected to your network. ...

Page 35

... Connect the power cable to 2-pin connector 2. Connect power cable to power adapter Figure 2-19 Power Connection for ADAM-4570/4570L/4570S/4571/4571L/ www.DataSheet4U.com Figure 2-20 Power Connection for EDG-4504 If the EDG Series is working properly, the green power LED will light up , indicating that the EDG Series is receiving power. Furthermore, the EDG Series provides surge protection to pro- ...

Page 36

... RJ-48 serial ports on the bottom of module. Depending on your serial device and serial interfaces, there are two options: 1. For an RS-232/422/485 (p.s. ADAM-4570S/4571S don't support RS-232) port you may use a RJ-48 to DB-9 cable which we supply to connect your serial device to the ADAM-4570/4570L/4570S/4571/4571L/4571S. Sim- ply plug one end of the cable into the jack, and plug the other end into the serial port jack on your serial device ...

Page 37

RJ-48 PIN Name DCD RJ- DTR GND Chapter 2 Getting Started DSR RTS ...

Page 38

... For an RS-232/422/485 port you may use a DB-9 cable to connect your serial device to the EDG-4504. Simply plug one end of the cable into the jack, and plug the other end into the serial port jack on your serial device. 2. The DB-9 pinouts is the same as ADAM-4570/4570L/4571 Figure 2-22 Serial Connection for EDG-4504 www.DataSheet4U.com 28 ...

Page 39

Installation and Configuration 3 ...

Page 40

... Use your Windows Explorer or the Windows Run command www.DataSheet4U.com to execute the Setup program.the path for the Setup program on the CD-ROM should be D:\ADAM-4570\utility&driver\ configutility1.01\setup.exe, if your default floppy drive is D:). Use the same way to execute the Setup program. The default path is C:\Program Files\Advantech\EDG COMport\1, 2 and 4 Configuration utility ...

Page 41

Configuring the EDG Series — The Configuration Utility The EDG Series provides easy Windows configuration through Ethernet connection. This Windows utility searches all the EDG Series and devices on the network automatically and you can configure various parameters for ...

Page 42

... EDG Series devices (see Figure 3-2) or select a group of ADAM-4570S/4571S (see Figure 3-3) or just select one ADAM-4570 (see Figure 3-4). When you select a specific de- vice, the LED that stands for “Status” will glow for 8 minutes. When you select another device, the original “Status” LED will turn off. Please follow these steps: 1. Select “ ...

Page 43

... The “Status” LED of all ADAM-4570S/4571S on the LAN will turn on 4. It’s the same way to locate one device. Figure 3-3 Locate the desired group of ADAM-4570S/4571S www.DataSheet4U.com Figure 3-4 Locate specific ADAM-4570S/4571S Chapter 3: Installation and Configuration 33 ...

Page 44

System Configuration Configuration utility can only search the EDG Series devices on the local network segment and cannot search beyond a router or gateway. Make sure that all the EDG Series devices that you want to monitor must reside ...

Page 45

Device Name Configuration utility provides a default name for device to distin- guish a specific EDG Series from other EDG Series. You can update the default device name based on your application. Names longer than 128 characters cannot be used. ...

Page 46

If you don't intend to have any encryption to protect your data transmission, just choose "NONE". The "Input Password" col- umn will be disable Type EDG Series offers three serial interfaces, RS-232, RS-485 and RS-422. You can use any one ...

Page 47

Network Configuration Figure 3-6 Network Configuration Window MAC Address This does not need configuration. Link Speed This function will show the current linking speed to be either 10Mbps or 100Mbps. However, the utility will auto-detect the current transmission speed ...

Page 48

IP address, Subnet Mask, Default Gateway The IP address identifies your EDG Series device on the global network. Each EDG Series has same default IP address 10.0.0.1. Obtain a specific IP address from your network administrator and then configure each ...

Page 49

... The EDG Series supports baud rates from 300 to 230,000 bps. Communication Switch Mode In ADAM-4570S/4571S, the utility allows the user to make a choice for communication switch mode. The default is “NONE” and the other two choices are host idle and device idle switch. ...

Page 50

... The purpose of the “Host Idle Switch” prevent system hung-up due to application program failure. If the program fails, ADAM-4570S/4571S will cut off the connection. Another application program or PC can then start to access. Similarly, when a serial device or connection fails to communicate with ADAM-4570S/4571S, the “ ...

Page 51

Status Messages The status message shown at the bottom of the utility window reflects the current status of EDG Series. “Read” The configuration utility has found the EDG Series and it is ready for use. www.DataSheet4U.com “Searching EDG COMport” ...

Page 52

Connection from the Device” Due to device shut down or network failure, the configuration utility has lost connection after 5 seconds. “Fail to apply this setting to the device” Specific settings are not accepted by EDG Series. “The device ...

Page 53

... Click ADD button to assign the COMport to the specific EDG Series. 3. Type IP address of the EDG Series and select ports. Note: If you assigned different COMport to the same ADAM- 4570’s port. The dialog box will appear to remind you. Chapter 3: Installation and Configuration Figure 3-10 Unused ports ...

Page 54

Figure 3-11 Assign COM port to EDG Series www.DataSheet4U.com 4. The port has been added into EDG Series 5. If you want to remove the COMport, click DELETE to re- move this. 44 Advantech EDG series User’s Manual Figure 3-12 ...

Page 55

... After you complete the configuration, click ”Apply”. 3.4.1 Security Setting When you select ADAM-4570S or ADAM-4571S in the col- umn "Model of Installed Device", the view of port mapping util- ity will change, as the figure shown below. www.DataSheet4U.com As you may have observed added with "Security" setting. ...

Page 56

... Self Test Function The purpose of this test is to make sure the communication from host PC to ADAM -4570 is OK. If there is still an error, you can check the communication from the EDG Series to the serial devices. If the test is selected, an external test will be done to check that the connection signals for each port are working properly ...

Page 57

Click the Test button in the Port Mapping utility. Signal Test ! • RTS • DTR ! • DTR ! www.DataSheet4U.com • DTR ! Communication Parameters Test • Baud rate: From 50 bps to 230 Kbps • Data bit: ...

Page 58

Click OK button to return to the port mapping window. All the ports in the EDG Series are tested ok. 3.4.3 Upgrading EDG Series’s Firmware Download Advantech continually upgrades its firmware to keep pace with the ever-expanding world of ...

Page 59

Click on the toolbar Update FW icon. 2. Locate and then select the filename of the firmware that you downloaded. www.DataSheet4U.com Chapter 3: Installation and Configuration Figure 3-15 Update firmware window Figure 3-16 Select the file 49 ...

Page 60

After downloading firmware completely, click on the Reboot button. The EDG Series will restart automati cally. Note: After clicking Reboot button, configuration utility will not reboot EDG Series untill no application program access this EDG Series. www.DataSheet4U.com 50 Advantech ...

Page 61

Save The Configuration If you want to save or recover the configuration, you can select the “Import/Export” items Select “File” b. Select “Import” or “Export” 2. Save or open the configurations www.DataSheet4U.com Chapter 3: Installation and Configuration ...

Page 62

Auto-reconnect function Sometimes, the system crashes because the EDG Series is inter- rupted or is powered-off by accident. Users want the host PC to re-connect to the EDG Series automatically after such an oc- currence. The EDG Series provides ...

Page 63

Troubleshooting ...

Page 64

This chapter explains how to solve some of the most common problems you could encounter while using EDG Series. If you are still having problems after reading this chapter, contact your dealer, or e-mail Advantech for help. “Configuration Utility can ...

Page 65

IP address or other server proper- ties” The network administrator is the only one allowed to modify the EDG Series’s configuration. Keep in mind, even when mul- tiple hosts share the same network, administrative access is still ...

Page 66

Advantech EDG series User’s Manual ...

Related keywords