HY29LV160 Hynix Semiconductor, HY29LV160 Datasheet - Page 23

no-image

HY29LV160

Manufacturer Part Number
HY29LV160
Description
16 Mbit (2M x 8/1M x 16) Low Voltage Flash Memory
Manufacturer
Hynix Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HY29LV160BF70I
Manufacturer:
KOR
Quantity:
20 000
Part Number:
HY29LV160BT-12W
Manufacturer:
PHI
Quantity:
74
Part Number:
HY29LV160BT-12W
Manufacturer:
HYUNDAI
Quantity:
20 000
Part Number:
HY29LV160BT-70
Manufacturer:
HY
Quantity:
3 000
Part Number:
HY29LV160BT-90
Manufacturer:
HY
Quantity:
3 000
Part Number:
HY29LV160BT-90
Manufacturer:
HYNIX
Quantity:
11 200
Part Number:
HY29LV160BT-90
Manufacturer:
HYNIX
Quantity:
221
Part Number:
HY29LV160BT-90I
Manufacturer:
HYUNDAI/KOREA
Quantity:
20 000
Part Number:
HY29LV160BT-90V
Manufacturer:
HYUNDAI
Quantity:
20 000
Part Number:
HY29LV160TT-90
Manufacturer:
KYOCERA/京瓷
Quantity:
20 000
For both of these conditions, the host must issue
a Reset command to return the device to the Read
mode.
DQ[3] - Sector Erase Timer
After writing a Sector Erase command sequence,
the host may read DQ[3] to determine whether or
not an erase operation has begun.
sector erase time-out expires and the sector erase
operation commences, DQ[3] switches from a ‘0’
to a ‘1’. Refer to the “Sector Erase Command”
section for additional information. Note that the
sector erase timer does not apply to the Chip Erase
command.
HARDWARE DATA PROTECTION
The HY29LV160 provides several methods of pro-
tection to prevent accidental erasure or program-
ming which might otherwise be caused by spuri-
ous system level signals during V
power-down transitions, or from system noise.
These methods are described in the sections that
follow.
Command Sequences
Commands that may alter array data require a
sequence of cycles as described in Table 6. This
provides data protection against inadvertent writes.
Low V
To protect data during V
down, the device does not accept write cycles
when V
command register and all internal program/erase
circuits are disabled, and the device resets to the
Read mode. Writes are ignored until V
than V
signals to the control pins to prevent unintentional
writes when V
Rev. 1.2/May 01
CC
LKO
CC
Write Inhibit
. The system must provide the proper
is less than V
CC
is greater than V
LKO
CC
(typically 2.4 volts). The
power-up and power-
CC
LKO
power-up and
.
CC
When the
is greater
After the initial Sector Erase command sequence
is issued, the system should read the status on
DQ[7] (Data# Polling) or DQ[6] (Toggle Bit I) to
ensure that the device has accepted the command
sequence, and then read DQ[3]. If DQ[3] is a ‘1’,
the internally controlled erase cycle has begun and
all further sector erase data cycles or commands
(other than Erase Suspend) are ignored until the
erase operation is complete. If DQ[3] is a ‘0’, the
device will accept a sector erase data cycle to mark
an additional sector for erasure. To ensure that
the data cycles have been accepted, the system
software should check the status of DQ[3] prior to
and following each subsequent sector erase data
cycle. If DQ[3] is high on the second status check,
the last data cycle might not have been accepted.
Write Pulse “Glitch” Protection
Noise pulses of less than 5 ns (typical) on OE#,
CE# or WE# do not initiate a write cycle.
Logical Inhibit
Write cycles are inhibited by asserting any one of
the following conditions: OE# = V
WE# = V
must be a logical zero while OE# is a logical one.
Power-Up Write Inhibit
If WE# = CE# = V
up, the device does not accept commands on the
rising edge of WE#. The internal state machine is
automatically reset to the Read mode on power-
up.
Sector Protection
Additional data protection is provided by the
HY29LV160’s sector protect feature, described
previously, which can be used to protect sensitive
areas of the Flash array from accidental or unau-
thorized attempts to alter the data.
IH
. To initiate a write cycle, CE# and WE#
IL
and OE# = V
IL
IH
, CE# = V
HY29LV160
during power
IH
, or
23