PIC16F627-04 Microchip Technology, PIC16F627-04 Datasheet - Page 64

no-image

PIC16F627-04

Manufacturer Part Number
PIC16F627-04
Description
FLASH-Based 8-Bit CMOS Microcontrollers
Manufacturer
Microchip Technology
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PIC16F627-04/P
Quantity:
31
Part Number:
PIC16F627-04/P
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
PIC16F627-04/SO
Manufacturer:
MIC
Quantity:
933
Part Number:
PIC16F627-04/SO
Manufacturer:
MICROCHI
Quantity:
20 000
Part Number:
PIC16F627-04/SS
Manufacturer:
MICROCHIP
Quantity:
13
Part Number:
PIC16F627-04/SS
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
PIC16F627-04I/P
Quantity:
18
Part Number:
PIC16F627-04I/P
Manufacturer:
MICR
Quantity:
20 000
Part Number:
PIC16F627-04I/SO
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
PIC16F62X
10.1
In Capture mode, CCPR1H:CCPR1L captures the
16-bit value of the TMR1 register when an event occurs
on pin RB3/CCP1. An event is defined as:
• every falling edge
• every rising edge
• every 4th rising edge
• every 16th rising edge
An event is selected by control bits CCP1M3:CCP1M0
(CCP1CON<3:0>). When a capture is made, the inter-
rupt request flag bit CCP1IF (PIR1<2>) is set. It must
be cleared in software. If another capture occurs before
the value in register CCPR1 is read, the old captured
value will be lost.
10.1.1
In Capture mode, the RB3/CCP1 pin should be config-
ured as an input by setting the TRISB<3> bit.
FIGURE 10-1: CAPTURE MODE OPERATION
10.1.2
Timer1 must be running in timer mode or synchronized
counter mode for the CCP module to use the capture
feature. In asynchronous counter mode, the capture
operation may not work.
10.1.3
When the Capture mode is changed, a false capture
interrupt may be generated. The user should keep bit
CCP1IE (PIE1<2>) clear to avoid false interrupts and
should clear the flag bit CCP1IF following any such
change in operating mode.
DS40300B-page 64
RB3/CCP1
Pin
Note:
Capture Mode
CCP PIN CONFIGURATION
TIMER1 MODE SELECTION
SOFTWARE INTERRUPT
If the RB3/CCP1 is configured as an out-
put, a write to the port can cause a capture
condition.
edge detect
Q’s
³ 1, 4, 16
Prescaler
and
CCP1CON<3:0>
BLOCK DIAGRAM
Set flag bit CCP1IF
(PIR1<2>)
Capture
Enable
CCPR1H
TMR1H
CCPR1L
TMR1L
Preliminary
10.1.4
There are four prescaler settings, specified by bits
CCP1M3:CCP1M0. Whenever the CCP module is
turned off, or the CCP module is not in capture mode,
the prescaler counter is cleared. This means that any
reset will clear the prescaler counter.
Switching from one capture prescaler to another may
generate an interrupt. Also, the prescaler counter will
not be cleared, therefore the first capture may be from
a non-zero prescaler.
mended method for switching between capture pres-
calers. This example also clears the prescaler counter
and will not generate the “false” interrupt.
EXAMPLE 10-1: CHANGING BETWEEN
CLRF
MOVLW
MOVWF
CCP1CON
NEW_CAPT_PS
CCP1CON
CCP PRESCALER
CAPTURE PRESCALERS
Example 10-1
;Turn CCP module off
;Load the W reg with
; the new prescaler
; mode value and CCP ON
;Load CCP1CON with this
; value
1999 Microchip Technology Inc.
shows the recom-

Related parts for PIC16F627-04