74HC688D,652 NXP Semiconductors, 74HC688D,652 Datasheet - Page 16

no-image

74HC688D,652

Manufacturer Part Number
74HC688D,652
Description
IC COMPARATOR MAGNITUDE 20SOIC
Manufacturer
NXP Semiconductors
Series
74HCr
Type
Magnitude Comparatorr

Specifications of 74HC688D,652

Package / Case
20-SOIC (7.5mm Width)
Number Of Bits
8
Delay Time - Propagation
8ns
Voltage - Supply
2 V ~ 6 V
Product
Digital Comparators
Output Type
Complementary
Input Bias Current (max)
0.008 mA
Supply Voltage (max)
6 V
Supply Voltage (min)
2 V
Maximum Operating Temperature
+ 125 C
Mounting Style
SMD/SMT
Minimum Operating Temperature
- 40 C
Propagation Delay Time
170 ns, 34 ns, 29 ns
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Supply
-
Operating Temperature
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
568-2727-5
933713900652

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
74HC688D,652
Manufacturer:
NXP
Quantity:
26
Philips Semiconductors
HCMOS family characteristics
FAMILY SPECIFICATIONS
AC CHARACTERISTICS
The “AC CHARACTERISTICS” table lists the guaranteed
limits when a device is tested under the conditions given in
the AC Test Circuits and Waveforms section.
TEST CIRCUITS
Good high-frequency wiring practices should be used in
test circuits. Capacitor leads should be as short as
possible to minimize ripples on the output waveform
transitions and undershoot. Generous ground metal
(preferably a ground-plane) should be used for the same
reasons. A V
decoupling capacitor should be provided
CC
at the test socket, also with short leads. Input signals
should have rise and fall times of 6 ns, a signal swing of
0 V to V
for 74HC and 0 V to 3 V for 74HCT; a 1.0 MHz
CC
square wave is recommended for most propagation delay
tests. The repetition rate must be increased for testing
f
. Two pulse generators are usually required for testing
max
such parameters as set-up time, hold time and removal
time. f
is also tested with 6 ns input rise and fall times,
max
with a 50% duty factor, but for typical f
as high as
max
60 MHz, there are no constraints on rise and fall times.
March 1988
16