MB15F03 Fujitsu Microelectronics, Inc., MB15F03 Datasheet - Page 12

no-image

MB15F03

Manufacturer Part Number
MB15F03
Description
Dual Serial Input Pll Frequency Synthesizer
Manufacturer
Fujitsu Microelectronics, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MB15F03LPFVI-G-BND-R-EF
Manufacturer:
FUJITSU/富士通
Quantity:
20 000
Part Number:
MB15F03PFV1
Manufacturer:
Winbond
Quantity:
7 311
Part Number:
MB15F03PFV1
Manufacturer:
FUJITSU/富士通
Quantity:
20 000
Part Number:
MB15F03PFV1-G
Manufacturer:
FUJITSU/富士通
Quantity:
20 000
Part Number:
MB15F03PFV1-G-BND-EF
Manufacturer:
FUJITSU
Quantity:
6 000
Company:
Part Number:
MB15F03PFV1-G-BND-ER
Quantity:
310
Part Number:
MB15F03SL
Manufacturer:
FUJITSU
Quantity:
434
Part Number:
MB15F03SLP
Manufacturer:
FUJITSU
Quantity:
3 000
Part Number:
MB15F03SLP
Manufacturer:
FUJITSU/富士通
Quantity:
20 000
Part Number:
MB15F03SLPF
Manufacturer:
FUJITSU/富士通
Quantity:
20 000
Part Number:
MB15F03SLPFV1
Manufacturer:
FUJITSU
Quantity:
5 222
Part Number:
MB15F03SLPV2-G-EF-6
Manufacturer:
FUJITSU
Quantity:
1 500
12
MB15F03
Setting a PS
be limited to 10 A (typ.). Setting PS pin to High, power saving mode is released so that the device works normally.
In addition, the intermittent operation control circuit is included which helps smooth start up from stand by mode.
In general, the power consumption can be saved by the intermittent operation that powering down or waking up the
synthesizer. Such case, if the PLL is powered up uncontrolled, the resulting phase comparator output signal is
unpredictable due to an undefined phase relation between reference frequency (fr) and comparison frequency (fp)
and may in the worst case take longer time for lock up of the loop.
To prevent this, the intermittent operation control circuit enforces a limited error signal output of the phase detector
during power up. Thus keeping the loop locked.
PS pin must be set “L” at Power-ON.
Allow 1 s after frequency stabilization on power-up for exiting the power saving mode (PS: L to H)
Serial data can be entered during the power saving mode.
During the power saving mode, the corresponding section except for indispensable circuit for the power saving
function stops working, then current consumption is reduced to 10 A per one PLL section.
At that time, the Do and LD become the same state as when a loop is locking. That is, the Do becomes high
impedance.
A VCO control voltage is naturally kept at the locking voltage which defined by a LPF’s time constant. As a result
of this, VCO’s frequency is kept at the locking frequency.
POWER SAVING MODE (INTERMITTENT MODE CONTROL CIRCUIT)
PS
H
H
L
L
IF
IF(RF)
PS
pin to Low, IF-PLL (RF-PLL) enters into power saving mode resultant current consumption can
H
H
L
L
RF
V
Clock
Data
LE
PS
CC
IF-PLL counters
OFF
OFF
(1) PS = L (power saving mode) at Power-ON.
(2) Set serial data after power supply remains stable.
(3) Release saving mode (PS: LfiH) after setting serial data.
ON
ON
i 1 j
RF-PLL counters
OFF
OFF
ON
ON
i 2 j
ON
OSC input buffer
i 3 j
OFF
ON
ON
ON