TC1054 TelCom Semiconductor, TC1054 Datasheet - Page 11
TC1054
Manufacturer Part Number
TC1054
Description
50mA CMOS LDO WITH SHUTDOWN AND ERROR OUTPUT
Manufacturer
TelCom Semiconductor
Datasheet
1.TC1054.pdf
(12 pages)
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TC1054-1.8VCT713
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
TC1054-2.5VCT713
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
TC1054-2.6VCT713
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
TC1054-2.7VCT713
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
TC1054-2.85VCT713
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Company:
Part Number:
TC1054-3.0VCT713
Manufacturer:
MICROCHIP
Quantity:
12 000
100mA CMOS LDO WITH SHUTDOWN
AND ERROR OUTPUT
is a function of the maximum ambient temperature (T
the maximum allowable die temperature (125 C) and the
thermal resistance from junction-to-air (
package has a
mounted on a single layer FR4 dielectric copper clad PC
board.
to ensure regulator thermal operation is within limits. For
example:
TC1055-01 6/5/97
I
Where:
V
LOAD MAX
V
OUT MIN
The maximum allowable power dissipation (Equation 2)
Equation 1 can be used in conjunction with Equation 2
Given:
Find:
Actual power dissipation:
Maximum allowable power dissipation:
IN MAX
P
Where all terms are previously defined.
P
D
D
V
= [(3.0 x 1.05) – (2.7 x .995)]40 x 10
= 18.5mW
= Worst case actual power dissipation
= Maximum voltage on V
= Minimum regulator output voltage
= Maximum output (load) current
V
OUT MIN
1. Actual power dissipation
2. Maximum allowable dissipation
(V
P
T
P
IN MAX
I
D
LOAD
AMAX
DMAX
IN MAX
P
D MAX
(V
JA
IN MAX
= 3.0V 5%
= 2.7V 0.5V
= 40mA
= 55 C
= (125 – 55)
= 318mW
= (T
– V
of approximately 220 C/Watt when
= (T
J MAX
OUT MIN
220
Equation 1.
Equation 2.
– V
J MAX
OUT MIN
– T
JA
) I
– T
LOAD MAX
A MAX
JA
J MAX )
) I
IN
LOAD MAX
)
JA
). SOT-23A-5
–3
A MAX
),
5
only 60mW; far below the allowable limit of 318mW. In a
similar manner, Equation 1 and Equation 2 can be used to
calculate maximum current and/or input voltage limits. For
example, the maximum allowable V
ing the maximum allowable power dissipation of 318mW
into Equation 1, from which V
Layout Considerations
is via the package leads. Therefore, layouts having a
ground plane, wide traces at the pads, and wide power
supply bus lines combine to lower
crease the maximum allowable power dissipation limit.
In this example, the TC1055 dissipates a maximum of
The primary path of heat conduction out of the package
PRELIMINARY INFORMATION
IN MAX
IN
= 5.9V.
is found by substitut-
JA
and therefore in-
TC1055