NET2-4231 Power-One, NET2-4231 Datasheet - Page 2

no-image

NET2-4231

Manufacturer Part Number
NET2-4231
Description
NET2 AC-DC Series
Manufacturer
Power-One
Datasheet
APR 19, 2005 revised to JUN 28, 2006
Input Specifications
PARAMETER
Input Voltage - AC
Input Frequency
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Power Factor
Output Specifications
PARAMETER
Efficiency
Ripple and Noise
Output Power
Overshoot / Undershoot
Regulation
Transient Response
Turn-on Delay
Turn-on Rise Time
Interface Signals and Internal Protection
PARAMETER
Overvoltage Protection
Overload Protection
Overtemperature Protection
Output Good
Input Power Fail Warning
Current Share
Remote Sense
CONDITIONS/DESCRIPTION
Continuous input range.
AC input.
After last AC line peak at 400 watts.
85 VAC at full rated load.
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 220 VAC, one cycle, 25°C.
Per EN61000-3-2 (Over the entire input range and above 60W load).
CONDITIONS/DESCRIPTION
Full Rated Load, 115 VAC. Varies with distribution of loads among outputs.
Full load, 20 MHz bandwidth.
With 460 LFM forced-air cooling (25 CFM through the power supply opening),
V1+V2+V3+V4+V5:
V1+V2 or V3+V4:
Output voltage overshoot/undershoot at turn-on.
Varies by output. Regulation includes: line changes over the specified
input range and changes in load between 0% and 100% load.
Recovery time, to within 1% of initial set point due to a 50% load change in
the load range of 10 to 100%; 3.5% or 100mV deviation, whichever is greater.
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90%.
CONDITIONS/DESCRIPTION
Overvoltage protection on all outputs except V5.
Unit latches off when overvoltage is detected.
AC input must be recycled to reset. V5 is protected by a 6.2V ±5%, 2W Zener diode.
Fully protected against output overload and short circuit. Automatic recovery upon
removal of overload condition. All outputs are individually current limited.
Power supply shuts down due to excessive internal overtemperature at the output
converter’s primary switching transistors. Power supply resets automatically upon
removal of the overtemperature cause.
TTL-compatible global Output Good signal. The signal is active when any of the
V1-V4 outputs drop >14% below nominal. Source impedance is 1k .
Open collector signal. Time before regulation dropout due to loss of input
power. May be used as independent PSOK signal in redundant applications.
Available on all outputs except V5. Accuracy of shared current with up
to two parallel units. Single wire current share is provided. For paralleling
more than two units, consult factory.
Available on all outputs except V5. Total voltage compensation for cable losses with
respect to the main output.
Page 2 of 5
NET2 AC-DC Series Data Sheet
V1/V4/V5:
V2/V3
0.95
MIN
MIN
MIN
85
47
20
120
5
See Model Selection Charts
See Model Selection Charts
TYP
TYP
0.5
1.5
TYP
85
20
10
1
www.power-one.com
MAX
MAX
MAX
264
400
200
140
500
3.5
63
7.0
35
2
A
W/VA
Watts
UNITS
UNITS
UNITS
VAC
A
Sec
mV
ms
RMS
ms
ms
ms
Hz
%
%
%
%
PK