6.4 Interface Timing
6.4.1 Timing Characteristics
Basically, interface timings should match the 1280x800 /60Hz manufacturing guide line timing.
document version 0.3 .
Note : DE mode only
Horizontal
Vertical
Section
Section
Clock frequency
Frame Rate
Parameter
Blanking
Blanking
Period
Period
Active
Active
Product Specification
AU OPTRONICS CORPORATION
Symbol
1/ T
T
T
T
T
T
T
-
HD
VD
VB
HB
Clock
V
H
Min.
1303
1280
803
800
50-
23
3
-
1408
1280
Typ.
69.3
816
800
136
60
16
Max.
1023
2047
1280
800
223
767
80-
-
T
Unit
MHz
T
Hz
Clock
Line
21 of 32