CLAA154WB03A CHUNGHWA PICTURE TUBES, CLAA154WB03A Datasheet - Page 5

no-image

CLAA154WB03A

Manufacturer Part Number
CLAA154WB03A
Description
Display Module
Manufacturer
CHUNGHWA PICTURE TUBES
Datasheet
CPT
2. ABSOLUTE MAXIMUM RATINGS
【Note】
CPT Confidential
The following are maximum value, which if exceeded, may cause faulty operation or damage to the unit.
specification. To place panel at room temp. ( 25±2 )below for 24hrs,nd then to measure TD with the same starting
lamp voltage in dark room.
Power Supply Voltage for LCD
Lamp voltage
Lamp current
Lamp frequency
Operation Temperature
Storage Temperature
Delayed Discharge Time
Before test TD, lamp should operate at least 1min, and lamp current should follow trpical lamp current
*1) Product life-time relate to lamp current, please operate production follow statement at page 9 〝(b)back light〞 .
*2) When lamp current over the definition of absolute max, product life-time will decay rapidly or operate
*3) The relative temperature and humidity range are as below sketch, 90%RH Max. (Ta 40 )
*4) The maximum wet bulb temperature
*5) If product in environment which over the definition of the relative temperature and humidity out of range too
*6) If you operate LCD in normal temperature range, the center surface of panel should be under 60 .
*7) Delay discharge time test condition :Starting lamp voltage=1650Vrms. (please follow statement at page 9
unusual.
long, it will affect visual of LCD.
〝 (b) back light〞
ITEM
-
20
Relative Humidity (%RH)
90
80
60
40
20
5
0
Temperature (°C)
SYMBOL
VCC
Tstg
Top
VL
TD
FL
IL
≦ ℃
25
39 (Ta
5/28
>40 ) and without dewing.
MIN.
www.DataSheet.net/
630
-25
40
40
--
0
2
0
(40,90)
50
(50,50.4)
MAX.
900
4.0
6.5
80
50
65
60
1
CHUNGHWA PICTURES TUBES, LTD.,
(60,27.7)
Operating Range
Storage
Range
CLAA154WB03A-STUDIO-V1-20071214
mArms
UNIT
Vrms
kHz
sec
V
www.yslcd.com.tw
≦ ℃
*3). 4). 5). 6)
REMARK
*3). 4). 5)
*1). 2)
*7)
Datasheet pdf - http://www.DataSheet4U.co.kr/

Related parts for CLAA154WB03A