MMA1200 Freescale Semiconductor, MMA1200 Datasheet - Page 2

no-image

MMA1200

Manufacturer Part Number
MMA1200
Description
Surface Mount Micromachined Accelerometer
Manufacturer
Freescale Semiconductor
Datasheet
MMA1200D
2
Table 1. Maximum Ratings
(Maximum ratings are the limits to which the device can be exposed without causing permanent damage.)
WARNING: This device is sensitive to electrostatic
2 kV ESD protection circuitry, extra precaution must be taken
by the user to protect the chip from ESD. A charge of over
2000 volts can accumulate on the human body or associated
test equipment. A charge of this magnitude can alter the
Powered Acceleration (all axes)
Unpowered Acceleration (all axes)
Supply Voltage
Drop Test
Storage Temperature Range
1. Dropped onto concrete surface from any axis.
Although the Freescale accelerometers contain internal
(1)
discharge.
Rating
ELECTRO STATIC DISCHARGE (ESD)
performance or cause failure of the chip. When handling the
accelerometer, proper ESD precautions should be followed
to avoid exposing the device to discharges which may be
detrimental to its performance.
Symbol
D
G
V
G
T
drop
upd
DD
stg
pd
–0.3 to +7.0
–40 to +125
Value
1500
2000
1.2
Freescale Semiconductor
Unit
°C
m
V
g
g
Sensors