si3201 Silicon Laboratories, si3201 Datasheet - Page 49

no-image

si3201

Manufacturer Part Number
si3201
Description
Proslic Programmable Cmos Slic With Ringing/battery Voltage Generation
Manufacturer
Silicon Laboratories
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
si3201-BS
Manufacturer:
SILICON
Quantity:
1 030
Part Number:
si3201-BS
Manufacturer:
SILICONLABS/芯科
Quantity:
20 000
Part Number:
si3201-FS
Manufacturer:
SI
Quantity:
1 000
Part Number:
si3201-FS
Manufacturer:
SI
Quantity:
20 000
Part Number:
si3201-FSR
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Company:
Part Number:
si3201-FSR
Quantity:
4 600
Part Number:
si3201-GS
Quantity:
5 510
Part Number:
si3201-GS
Manufacturer:
SILICON
Quantity:
17
Part Number:
si3201-KS
Manufacturer:
SILICON
Quantity:
18
Part Number:
si3201-KS
Manufacturer:
SILICONIX
Quantity:
20 000
Part Number:
si3201-KSR
Manufacturer:
ELANTEC
Quantity:
50 000
Part Number:
si3201-KSR
Manufacturer:
SILICON LABS/芯科
Quantity:
20 000
Company:
Part Number:
si3201-KSR
Quantity:
194
Register 15. Power Down Control 2
Reset settings = 0000_0000
Name
Type
Bit
7:6
Bit
5
4
3
2
1
0
Reserved
ADCON
DACON
GMON
ADCM
DACM
Name
D7
GMM
D6
Read returns zero.
Analog to Digital Converter Manual/Automatic Power Control.
0 = Automatic power control.
1 = Manual power control; ADCON controls on/off state.
Analog to Digital Converter On/Off Power Control.
When ADCM = 1:
0 = Analog to digital converter powered off.
1 = Analog to digital converter powered on.
ADCON has no effect when ADCM = 0.
Digital to Analog Converter Manual/Automatic Power Control.
0 = Automatic power control.
1 = Manual power control; DACON controls on/off state.
Digital to Analog Converter On/Off Power Control.
When DACM = 1:
0 = Digital to analog converter powered off.
1 = Digital to analog converter powered on.
DACON has no effect when DACM = 0.
Transconductance Amplifier Manual/Automatic Power Control.
0 = Automatic power control.
1 = Manual power control; GMON controls on/off state.
Transconductance Amplifier On/Off Power Control.
When GMM = 1:
0 = Analog to digital converter powered off.
1 = Analog to digital converter powered on.
GMON has no effect when GMM = 0.
ADCM
R/W
D5
ADCON
Preliminary Rev. 0.96
R/W
D4
DACM
R/W
D3
Function
DACON
R/W
D2
GMM
R/W
D1
GMON
R/W
D0
Si3230
49

Related parts for si3201