si2493 Silicon Laboratories, si2493 Datasheet - Page 35

no-image

si2493

Manufacturer Part Number
si2493
Description
V.92 Isomodem With Global Daa
Manufacturer
Silicon Laboratories
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
si2493-C-FSR
Manufacturer:
DY
Quantity:
8 623
Part Number:
si2493-C-FSR
Manufacturer:
SIEMENS/西门子
Quantity:
20 000
Part Number:
si2493-C-FT
Manufacturer:
Silicon Labs
Quantity:
135
Part Number:
si2493-C-FTR
Manufacturer:
SIEMENS/西门子
Quantity:
20 000
Company:
Part Number:
si2493-C-FTR
Quantity:
1 559
Part Number:
si2493-D-FS
Manufacturer:
SILICON
Quantity:
3 483
Part Number:
si2493-F-FSR
Quantity:
587
Part Number:
si2493-FS
Manufacturer:
SILICON
Quantity:
352
Part Number:
si2493-FS
Manufacturer:
SI
Quantity:
20 000
Part Number:
si2493-FT
Manufacturer:
SI
Quantity:
20 000
Part Number:
si2493-KT
Manufacturer:
SILICONIX
Quantity:
20 000
Command
%On
%O1
%O2
%Cn
%C0
%C1
%C2
%C3
%Vn
%V0
%V1
%B
%$
Display AT% command settings.
Report blacklist. See also S42 register.
Data compression
Disable V.42bis and MNP5 data compression
Enable V.42bis in transmit and receive paths. If MNP is selected (\N2), then %C1 enables
MNP5 in transmit and receive paths.
Enable V.42bis in transmit path only.
Enable V.42bis in receive path only.
Answer mode.
Si2493 will auto-answer a call in answer mode.
Si2493 will auto-answer a call in originate mode.
Automatic Line Status Detection.
After the %V1 and %V2 commands are issued, the Si2493 will automatically check the telephone
connection for whether or not a line is present. If a line is present, the Si2493 will automatically
check if the line is already in use. Finally, the Si2493 will check line status both before going off-hook
and again before dialing. %V1 uses the fixed method, and %V2 uses the adaptive method. %V0
(default) disables this feature.
Disable automatic line-in-use detection.
Automatic Line Status Detection—Fixed Method.
Description: Before going off-hook with the ATD, ATO, or ATA commands, the Si2493 compares the
line voltage (via LVCS) to registers NOLN (U83) and LIUS (U84):
Loop Voltage
0  LVCS  NOLN
NOLN  LVCS  LIUS
LIUS  LCVS
Once the call has begun, the off-hook intrusion algorithm (described in "4.15.2. Off-Hook Intrusion
Detection" on page 20) operates normally. In addition, the Si2493 will report “NO LINE” if the tele-
phone line is completely disconnected. If the HOI bit (U77, bit 11) is set, “LINE IN USE” is reported
upon intrusion.
Table 10. Extended AT% Command Set (Command Defaults in Bold)
Action
Report “NO LINE” and remain on-hook.
Report “LINE IN USE” and remain on-hook.
Go off-hook and establish a modem connection.