cs10.481 B&B Electronics Mfg, cs10.481 Datasheet - Page 12

no-image

cs10.481

Manufacturer Part Number
cs10.481
Description
48v, 5a, Single Phase Input
Manufacturer
B&B Electronics Mfg
Datasheet
17. S
18. D
Input / output separation
Class of protection
Isolation resistance
PE resistance
Touch current (leakage current)
The output voltage is floating and has no ohmic connection to ground.
To fulfill the PELV requirements according to EN60204-1 § 6.4.1, we recommend that either the + pole, the – pole or
any other part of the output circuit shall be connected to the protective earth system. This helps to avoid situations in
which a load starts unexpectedly or can not be switched off any more when unnoticed earth faults occur.
Nov. 2006 / Rev.1.1 DS-CS10.481-EN
All parameters are specified at 48V, 5A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
AFETY
Input
Earth, PE
IELECTRIC
N
L
A
Fig. 18-1 Dielectric strength
C–Series
S
TRENGTH
Output
www.pulspower.com Phone +49 89 9278 0
SELV
PELV
double or reinforced insulation
I
> 5MOhm
< 0.1Ohm
typ. 0.36mA
typ. 0.50mA
typ. 0.64mA
< 0.45mA
< 0.62mA
< 0.85mA
+
-
Type test
Factory test
Field test
Type tests and factory tests:
Conducted by the manufacturer. Do not repeat test in field!
Rules for field test:
Use appropriate test equipment which applies the voltage
with a slow ramp! Connect L and N together as well as all
output poles.
IEC/EN 60950-1
EN 60204-1, EN 50178, IEC 60364-4-41
PE (Protective Earth) connection required
input to output, 500Vdc
between housing and PE terminal
100Vac, 50Hz, TN mains
120Vac, 60Hz, TN mains
230Vac, 50Hz, TN mains
110Vac, 50Hz, TN mains
132Vac, 60Hz, TN mains
264Vac, 50Hz, TN mains
60s
5s
5s
Germany
2500Vac
2500Vac
2000Vac
48V, 5A, S
A
3000Vac
2500Vac
2000Vac
INGLE
B
CS10.481
P
HASE
500Vac
500Vac
500Vac
I
C
NPUT
12/20