z16017 ZiLOG Semiconductor, z16017 Datasheet - Page 60

no-image

z16017

Manufacturer Part Number
z16017
Description
Pcmcia Interface Solution
Manufacturer
ZiLOG Semiconductor
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
z1601720ASC
Quantity:
7 784
Part Number:
z1601720ASC1868
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
z1601720ASC1868TR
Manufacturer:
Zilog
Quantity:
10 000
Part Number:
z1601720ASG1868
Manufacturer:
Zilog
Quantity:
10 000
46
EEPROM Register
Address: SELECT 04h
Name: Interface Configuration Register 3
Type: Read/Write
PS012002-1201
Bit Placement
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Z86017/Z16017 PCMCIA Interface Solution
Product Specification
Table 20.
Bit Name
SEL_PRIMARY_1x
SEL_PRINARY_3x
SEL_SECOND_1x
SEL_SECOND_3x
STR_RST
EN_DIS_RST
EN_PDIAG_INT
EN_PDIAG_EXT
Interface Configuration Register 3: Address 04h
Description
Enables IDE/PCMCIA access to primary task file
addresses 1F<0-7>. This bit is active when set to 1. On
Power-On Reset, this bit is set to 0.
Enables IDE/PCMCIA access to primary task file
addresses 3F<6-7>. Active when set to 1. On Power-On
Reset, this bit is set to 0 (Table 21).
Enables IDE/PCMCIA access to secondary task file
addresses 17<0-7>. Active when set to 1. On Power-On
Reset, this bit is set to 0.
Enables IDE/PCMCIA access to secondary task file
addresses 37<0-7>. Active when set to 1. On Power-On
Reset, this bit is set to 0.
Switching this bit from Low to High to Low again forces
the ZX6017 to check the level on PC_ATA/HOE pin and
latch the mode. This bit is active when set to 1. On Power-
On Reset, this bit is set to 0.
Disable PCMCIA reset. This bit is active when set to 1.
Resets from the PCMCIA bus are not allowed. On Power-
On Reset, this bit is set to 0 (Table 22).
When this bit is set to 1, PDIAG is generated internally. On
Power-On Reset, this bit is set to 0. Also see Registers 02h
and 07h (Table 14 and Table 26).
When this bit is set to 1, PDIAG is generated externally
through the AT_PDIAG pin on the local AT side. On
Power-On Reset, this bit is set to 0. Also see Registers 02h
and 07h (Table 14 and Table 26).
Programming Internal Registers

Related parts for z16017