pca9624 NXP Semiconductors, pca9624 Datasheet - Page 13

no-image

pca9624

Manufacturer Part Number
pca9624
Description
8-bit Fm+ I2c-bus 100 Ma 40 V Led Driver
Manufacturer
NXP Semiconductors
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
pca9624PW
Manufacturer:
PHILIPS
Quantity:
5 542
Part Number:
pca9624PW
Manufacturer:
NXP
Quantity:
2 924
Part Number:
pca9624PW
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Company:
Part Number:
pca9624PW
Quantity:
5 000
Part Number:
pca9624PW,112
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
pca9624PW,118
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
pca9624PW118
Manufacturer:
NXP Semiconductors
Quantity:
135
Part Number:
pca9624PWЈ¬112
Manufacturer:
NXP
Quantity:
551
NXP Semiconductors
PCA9624_1
Product data sheet
7.3.7 SUBADR1 to SUBADR3, I
7.3.8 ALLCALLADR, LED All Call I
Table 11.
Legend: * default value.
Subaddresses are programmable through the I
E4h, E8h, and the device(s) will not acknowledge these addresses right after power-up
(the corresponding SUBx bit in MODE1 register is equal to 0).
Once subaddresses have been programmed to their right values, SUBx bits need to be
set to logic 1 in order to have the device acknowledging these addresses (MODE1
register).
Only the 7 MSBs representing the I
register is a read-only bit (0).
When SUBx is set to logic 1, the corresponding I
either an I
Table 12.
Legend: * default value.
The LED All Call I
at the same time (ALLCALL bit in register MODE1 must be equal to 1 (power-up default
state)). This address is programmable through the I
an I
Sub Call.
Only the 7 MSBs representing the All Call I
ALLCALLADR register is a read-only bit (0).
If ALLCALL bit = 0, the device does not acknowledge the address programmed in register
ALLCALLADR.
Address
0Eh
0Fh
10h
Address
11h
2
C-bus read or write sequence. The register address can also be programmed as a
2
Register
SUBADR1
SUBADR2
SUBADR3
Register
ALLCALLADR
SUBADR1 to SUBADR3 - I
10h) bit description
ALLCALLADR - LED All Call I
bit description
C-bus read or write sequence.
2
C-bus address allows all the PCA9624s on the bus to be programmed
Rev. 01 — 3 June 2009
Bit
7:1
0
7:1
0
7:1
0
Bit
7:1
0
2
C-bus subaddress 1 to 3
Symbol
A1[7:1]
A1[0]
A2[7:1]
A2[0]
A3[7:1]
A3[0]
Symbol
AC[7:1]
AC[0]
2
C-bus address
2
2
C-bus subaddress are valid. The LSB in SUBADRx
C-bus subaddress registers 0 to 3 (address 0Eh to
2
C-bus address register (address 11h)
Access Value
R/W
R only
R/W
R only
R/W
R only
2
Access Value
R/W
R only
C-bus address are valid. The LSB in
8-bit Fm+ I
2
C-bus. Default power-up values are E2h,
2
C-bus subaddress can be used during
2
1110 001*
0*
1110 010*
0*
1110 100*
0*
C-bus and can be used during either
1110 000*
0*
2
C-bus 100 mA 40 V LED driver
Description
I
reserved
I
reserved
I
reserved
2
2
2
Description
ALLCALL I
address register
reserved
C-bus subaddress 1
C-bus subaddress 2
C-bus subaddress 3
PCA9624
© NXP B.V. 2009. All rights reserved.
2
C-bus
13 of 34

Related parts for pca9624