mic3002 Micrel Semiconductor, mic3002 Datasheet - Page 16

no-image

mic3002

Manufacturer Part Number
mic3002
Description
Mic3002 Fom Management Ic With Internal Calibration
Manufacturer
Micrel Semiconductor
Datasheet
Micrel, Inc.
July 2007
HEX
00-3F
40-7F
80-BF
C0-FF
HEX
00
01
02
03
04
05
06
07
08
09
0A
0B
0C-0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C-1D
1E
1F
Address(s)
Address(s)
DEC
0-63
64-127
128-191
192-255
DEC
0
1
2
3
4
5
6
7
8
9
10
11
12-15
16
17
18
19
20
21
22
23
24
25
26
27
28-29
30
31
Field Size
(Bytes)
64
64
64
64
Field Size
(Bytes)
1
1
1
1
1
1
1
1
1
1
1
1
4
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
Table 3. Temperature Compensation Tables, Serial Address = A4
Name
BIASLUT1
MODLUT1
IFTLUT1
HATLUT1
Name
OEMCFG0
OEMCFG1
OEMCFG2
APCSET0
APCSET1
APCSET2
MODSET0
IBFLT
TXPFLT
LOSFLT
FLTTMR
FLTMSK
OEMPWSET
OEMCAL0
OEMCAL1
LUTINDX
OEMCFG3
APCDAC
MODDAC
OEMREAD
LOSFLTn
RXPOT
OEMCFG4
OEMCFG5
OEMCFG6
SCRATCH
MODSET 1
MODSET 2
Description
Bias temperature compensation L.U.T. first 64 entries. Additional 12
entries are located in A6: 90-9B.
Modulation temperature compensation L.U.T. first 64 entries. Additional
12 entries are located in A6: A0-AB.
Bias current fault threshold temperature compensation L.U.T. first 64
entries. Additional 12 entries are located in A6: B0-BB.
Bias current high alarm threshold temperature compensation L.U.T. first
64 entries. Additional 12 entries are located in A6: C0-CB.
Description
OEM configuration register 0
OEM configuration register 1
OEM configuration register 2
APC setpoint register 0
APC setpoint register 1
APC setpoint register 2
Modulation setpoint register 0
Bias current fault-comparator threshold. This register is temperature
compensated
TX power fault threshold
RX LOS fault-comparator threshold
Fault comparator timer setting
Fault source mask bits
Password for access to OEM areas
OEM calibration register 0
OEM calibration register 1
Look-up table index read-back
OEM configuration register 3
Reads back current APC DAC value (setpoint+offset)
Reads back current modulation DAC value (setpoint+offset)
Reads back OEM calibration data
LOS De-assert threshold
RXPOT tap selection
OEM configuration register 4
OEM configuration register 5
OEM configuration register 6
Reserved – do not write; reads undefined.
Modulation setpoint register 1
Modulation setpoint register 2
16
hbwhelp@micrel.com
h
or (408) 955-1690
M9999-073107-B
MIC3002

Related parts for mic3002