mic3003gfltr Micrel Semiconductor, mic3003gfltr Datasheet - Page 8

no-image

mic3003gfltr

Manufacturer Part Number
mic3003gfltr
Description
Fom Management Ic With Internal Calibration
Manufacturer
Micrel Semiconductor
Datasheet
Micrel, Inc.
July 2010
Pin Configuration
Pin Description (MIC3003GFL only)
Pin Number
10
11
1
2
3
4
5
6
7
8
9
TXDISABLE
Pin Name
TXFAULT
VIN/INT
QGPO
GNDD
VDDD
DATA
RS0
VRX
CLK
RS1
Pin Function
Power supply input for digital functions.
Open-drain output. Can be selected (via OEMCFG3 bit 7) to be an open-drain GPO or an active-
low, open-drain, pulsed reset signal output controlled by the status of bits [0-2] of byte A2h: FFh.
Ground return for digital functions.
Digital input. Receiver Rate Select input. OR’ed with soft rate select bit SRS0 to determine the
state of the RRSOUT pin. The state of this pin is always reflected in the RS0S bit.
If bit 4 (IE) in the USRCTL register is set to 0 (its default value), this pin is configured as an analog
input. If IE bit is set to 1, this pin is configured as an open-drain output.
Analog input: Multiplexed A/D input for monitoring supply voltage, with a 0V to 5.5V input range.
Open-drain output: outputs the internally generated active-low interrupt signal /INT.
Digital input. Serial clock input.
Digital I/O, open-drain, bi-directional serial data input/output.
Digital input; Active high. The transmitter is disabled when this input is high or the STXDIS bit is
set to 1. The state of this input is always reflected in the TXDIS bit.
Digital Output; Open-Drain, with programmable polarity. If OEMCFG5 bit 4 is set to 0, a high level
indicates a hardware fault impeding transmitter operation. If OEMCFG5 bit 4 is set to 1, a low level
indicates a hardware fault impeding transmitter operation. The state of this pin is always reflected
in the TXFLT bit.
Digital Input; Transmitter Rate Select Input; OR’ed with soft rate select bit SRS1 to determine the
state of the TRSOUT pin. The state of this pin is always reflected in the RS1S bit.
Analog Input. Multiplexed A/D converter input for monitoring received optical power. The input
range is 0 to V
ranging of the RX power measurement.
REF
. A 5-bit programmable EEPOT on this pin provides coarse calibration and
24-Pin MLF
®