mode.
CONFREG0
CONFREG0 bit functions
Bit
IROUTC[1:0]
TOUTC[1.0]
SUBINC
SUBDEC
NTC
TIMEOS[3:0]
OSCCTRL
Read access: No. The data is accessible for read via SPI only from eeprom address 05h.
Write access: Only in test mode for both writing directly to internal registers and writing to Eeprom if WP
register is correctly set.
BGO: Reserved
Read access: No. The data is accessible for read via SPI only from eeprom address 06h.
Write access: Only in test mode for both writing directly to internal registers and writing to Eeprom if the
WP register is correctly set.
LPF
Read access: No. The data is accessible for read via SPI only from eeprom address 07h.
MLX90313 Programmable IR sensor Interface
3901090313
POR
val
00b
01b
10b
11b
00b
01b
10b
11b
0
1
0
1
0
1
0000
0001
0010
0011
0100
0101
0110
0111
1000
1001
1010
1011
1100
1101
1110
1111
Function
IROUT pin function: IR-chain out
IROUT pin function: Linear Tobject
IROUT pin function: Threshold Rel1 input
IROUT pin function: PWM out
TEMPOUT pin function: Temp-chain out
TEMPOUT pin function: Linear Tambient
TEMPOUT pin function: Comp1 out
TEMPOUT pin function: PWM out
2nd order derivative of thermistor function is positive (used if NTC=0)
2nd order derivative of thermistor function is negative (used if NTC=0)
2nd order derivative of thermistor function is positive (used if NTC=1)
2nd order derivative of thermistor function is negative (used if NTC=1)
Used thermistor is PTC
Used thermistor is NTC
Offset calibration interval: 0'00"
Offset calibration interval: 0'02"
Offset calibration interval: 0'17"
Offset calibration interval: 0'19"
Offset calibration interval: 1'07"
Offset calibration interval: 1'09"
Offset calibration interval: 1'24"
Offset calibration interval: 1'26"
Offset calibration interval: 2'14"
Offset calibration interval: 2'16"
Offset calibration interval: 2'31"
Offset calibration interval: 2'33"
Offset calibration interval: 3'21"
Offset calibration interval: 3'23"
Offset calibration interval: 3'38"
Offset calibration interval: 3'40"
Page 17
Programmable IR Sensor Interface
MLX90313