mlx90316 Melexis Company, mlx90316 Datasheet - Page 24

no-image

mlx90316

Manufacturer Part Number
mlx90316
Description
Rotary Position Sensor Ic
Manufacturer
Melexis Company
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
mlx90316-LDC-BDG
Manufacturer:
MELEXIS
Quantity:
3 550
Part Number:
mlx90316-LDC-BDG-SPI
Manufacturer:
MELEXIS
Quantity:
3 550
Part Number:
mlx90316BAC
Manufacturer:
MELEXIS
Quantity:
5 305
Part Number:
mlx90316DKC-BCG
Manufacturer:
MELEXIS/迈来芯
Quantity:
20 000
Part Number:
mlx90316EDC-BCG-000-RE
Manufacturer:
INFINEON
Quantity:
101
Part Number:
mlx90316EDC-BCG-000-RE
Manufacturer:
MELEXIS/迈来芯
Quantity:
20 000
Part Number:
mlx90316KDC
Manufacturer:
MELEXIS/迈来芯
Quantity:
20 000
Part Number:
mlx90316KDC-BCG
Manufacturer:
MELEXIS/迈来芯
Quantity:
20 000
Part Number:
mlx90316KDC-BCG-000-RE
Manufacturer:
MAXIM
Quantity:
1 400
Part Number:
mlx90316KDC-BCG-000-RE
Manufacturer:
MELEXIS/迈来芯
Quantity:
20 000
Part Number:
mlx90316KDC-BCG-000-RE
0
14.6. Programmable Diagnostic Settings
14.6.1. RESONFAULT Parameter
This RESONFAULT parameter disables the soft reset when a fault is detected by the CPU when the
parameter is set to 1. By default, the parameter is set to “0” but it is recommended to set it to “1” to
activate the self diagnostic modes (See section 15).
Note that in the User Interface (MLX90316UI), the RESONFAULT is split in two bits:
14.6.2. EEHAMHOLE Parameter
The EEHAMHOLE parameter disables the memory recovery (Hamming code) check when a fault is
detected by the CRC when it is equal to 3131h. By default the parameter is set to 0 (enable memory
recovery).
14.7. Lock
14.7.1. MLXLOCK Parameter
MLXLOCK locks all the parameters set by Melexis.
14.7.2. LOCK Parameter
LOCK locks all the parameters set by the user. Once the lock is enabled, it is not possible to change the
EEPROM values anymore.
Note that the lock bit should be set by the solver function “MemLock”.
3901090316
Rev. 003
DRESONFAULT: disable the reset in case of a fault.
DOUTINFAULT: disable output in diagnostic low in case of fault.
RESONFAULT
EEHAMHOLE
Parameter
Parameter
MLXLOCK
LOCK
Page 24 of 41
3131h
Value
Value
0
1
0
0
1
0
1
Rotary Position Sensor IC