mlx90316 Melexis Company, mlx90316 Datasheet - Page 27

no-image

mlx90316

Manufacturer Part Number
mlx90316
Description
Rotary Position Sensor Ic
Manufacturer
Melexis Company
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
mlx90316-LDC-BDG
Manufacturer:
MELEXIS
Quantity:
3 550
Part Number:
mlx90316-LDC-BDG-SPI
Manufacturer:
MELEXIS
Quantity:
3 550
Part Number:
mlx90316BAC
Manufacturer:
MELEXIS
Quantity:
5 305
Part Number:
mlx90316DKC-BCG
Manufacturer:
MELEXIS/迈来芯
Quantity:
20 000
Part Number:
mlx90316EDC-BCG-000-RE
Manufacturer:
INFINEON
Quantity:
101
Part Number:
mlx90316EDC-BCG-000-RE
Manufacturer:
MELEXIS/迈来芯
Quantity:
20 000
Part Number:
mlx90316KDC
Manufacturer:
MELEXIS/迈来芯
Quantity:
20 000
Part Number:
mlx90316KDC-BCG
Manufacturer:
MELEXIS/迈来芯
Quantity:
20 000
Part Number:
mlx90316KDC-BCG-000-RE
Manufacturer:
MAXIM
Quantity:
1 400
Part Number:
mlx90316KDC-BCG-000-RE
Manufacturer:
MELEXIS/迈来芯
Quantity:
20 000
Part Number:
mlx90316KDC-BCG-000-RE
0
16.
16.1. Introduction
The MLX90316 features a digital Serial Protocol mode. The MLX90316 is considered as a Slave node.
The serial protocol of the MLX90316 is a three wires protocol (/SS, SCLK, MOSI-MISO):
The basic knowledge of the standard SPI specification is required for the good understanding of the
present section.
16.2. SERIAL PROTOCOL Mode
The positive going edge shifts a bit to the Slave’s output stage and the negative going edge samples the
bit at the Master’s input stage.
16.3. MOSI (Master Out Slave In)
The Master sends a command to the Slave to get the angle information.
16.4. MISO (Master In Slave Out)
The MISO of the slave is an open-collector stage. Due to the capacitive load (TBD) a >1 kΩ pull-up is
used for the recessive high level (in fast mode). Note that MOSI and MISO use the same physical pin of
the MLX90316.
16.5. /SS (Slave Select)
The /SS pin enables a frame transfer (if CPHA = 1). It allows a re-synchronization between Slave and
Master in case of communication error.
16.6. Master Start-Up
/SS, SCLK, MISO can be undefined during the Master start-up as long as the Slave is re-synchronized
before the first frame transfer.
16.7. Slave Start-Up
The slave start-up (after power-up or an internal failure) takes 16 ms. Within this time /SS and SCLK is
ignored by the Slave. The first frame can therefore be sent after 16 ms. MISO is Hi-Z (i.e. Hi-Impedance)
until the Slave is selected by its /SS input. MLX90316 will cope with any signal from the Master while
starting up.
3901090316
Rev. 003
Serial Protocol
/SS pin is a 5 V tolerant digital input
SCLK pin is a 5 V tolerant digital input
MOSI-MISO pin is a 5 V tolerant open drain digital input/output
CPHA = 1
CPOL = 0
even clock changes are used to sample the data
active-Hi clock
Page 27 of 41