w83977ctf Winbond Electronics Corp America, w83977ctf Datasheet - Page 77

no-image

w83977ctf

Manufacturer Part Number
w83977ctf
Description
Winbond I/o
Manufacturer
Winbond Electronics Corp America
Datasheet
5.2.7 EPP Pin Descriptions
5.2.8 EPP Operation
When the EPP mode is selected in the configuration register, the standard and bi-directional modes
are also available. The PDx bus is in the standard or bi-directional mode when no EPP read, write, or
address cycle is currently being executed. In this condition all output signals are set by the SPP
Control Port, and the direction is controlled by DIR of the Control Port.
A watchdog timer is required to prevent system lockup. The timer indicates that more than 10 S
have elapsed from the start of the EPP cycle to the time
cycle is aborted when a time-out occurs. The time-out condition is indicated in Status bit 0.
The EPP operates on a two-phase cycle. First, the host selects the register within the device for
subsequent operations. Second, the host performs a series of read and/or write byte operations to the
selected register. Four operations are supported on the EPP: Address Write, Data Write, Address
Read, and Data Read. All operations on the EPP device are performed asynchronously.
The EPP read/write operation can be completed under the following conditions:
a. If the nWait is active low, when the read cycle (nWrite inactive high, nDStrb/nAStrb active low) or
write cycle (nWrite active low, nDStrb/nAStrb active low) starts, the read/write cycle proceeds
normally and will be completed when nWait goes inactive high.
b. If nWait is inactive high, the read/write cycle will not start. It must wait until nWait changes to
active low, at which time it will start as described above.
The EPP read/write cycle can start without checking whether nWait is active or inactive. Once the
read/write cycle starts, however, it will not terminate until nWait changes from active low to inactive
high.
nWrite
PD<0:7>
Intr
nWait
PE
Select
nDStrb
nError
nInits
nAStrb
EPP NAME
5.2.8.1
5.2.8.2
5.2.8.3
EPP Operation
EPP Version 1.9 Operation
EPP Version 1.7 Operation
TYPE
I/O
O
O
O
O
I
I
I
I
I
Denotes an address or data read or write operation.
Bi-directional EPP address and data bus.
Used by peripheral device to interrupt the host.
Inactive to acknowledge that data transfer is completed. Active to
indicate that the device is ready for the next transfer.
Paper end; same as SPP mode.
Printer selected status; same as SPP mode.
This signal is active low. It denotes a data read or write operation.
Error; same as SPP mode.
This signal is active low. When it is active, the EPP device is reset to its
initial operating mode.
This signal is active low. It denotes an address read or write operation.
-68 -
EPP DESCRIPTION
WAIT#
Publication Release Date: March 1999
is deasserted. The current EPP
W83977EF/ CTF
PRELIMINARY
Revision A1

Related parts for w83977ctf