WRITE STATUS REGISTER (WRSR): The WRSR instruction allows the user to select one of four levels of protec-
tion. The AT25010B/020B/040B is divided into four array segments. One-quarter, one-half, or all of the memory
segments can be protected. Any of the data within any selected segment will therefore be read only. The block
write protection levels and corresponding status register control bits are shown in
Bits BP1 and BP0 are nonvolatile cells that have the same properties and functions as the regular memory cells
(e.g., WREN, t
Table 3-4.
READ SEQUENCE (READ): Reading the AT25010B/020B/040B via the SO pin requires the following sequence.
After the CS line is pulled low to select a device, the read op-code (including A8) is transmitted via the SI line fol-
lowed by the byte address to be read (A7A0). Upon completion, any data on the SI line will be ignored. The data
(D7D0) at the specified address is then shifted out onto the SO line. If only one byte is to be read, the CS line
should be driven high after the data comes out. The read sequence can be continued since the byte address is
automatically incremented and data will continue to be shifted out. When the highest address is reached, the
address counter will roll over to the lowest address allowing the entire memory to be read in one continuous read
cycle.
WRITE SEQUENCE (WRITE): In order to program the AT25010B/020B/040B, the Write Protect pin (WP) must be
held high and two separate instructions must be executed. First, the device must be write enabled via the WREN
instruction. Then a Write (WRITE) instruction may be executed. Also, the address of the memory location(s) to be
programmed must be outside the protected address field location selected by the block write protection level. Dur-
ing an internal write cycle, all commands will be ignored except the RDSR instruction.
A Write instruction requires the following sequence. After the CS line is pulled low to select the device, the WRITE
op-code (including A8) is transmitted via the SI line followed by the byte address (A7A0) and the data (D7D0) to
be programmed. Programming will start after the CS pin is brought high. The low-to-high transition of the CS pin
must occur during the SCK low time immediately after clocking in the D0 (LSB) data bit.
The ready/busy status of the device can be determined by initiating a Read Status Register (RDSR) instruction. If
Bit 0 = “1”, the write cycle is still in progress. If Bit 0 = “0”, the write cycle has ended. Only the RDSR instruction is
enabled during the write programming cycle.
The AT25010B/020B/040B is capable of an 8-byte page write operation. After each byte of data is received, the
three low-order address bits are internally incremented by one; the six high-order bits of the address will remain
constant. If more than 8 bytes of data are transmitted, the address counter will roll over and the previously written
data will be overwritten. The AT25010B/020B/040B is automatically returned to the write disable state at the com-
pletion of a write cycle.
Note:
AT25010B/020B/040B [Preliminary]
Level
1 (1/4)
2 (1/2)
3 (All)
0
If the WP pin is brought low or if the device is not write enabled (WREN), the device will ignore the Write instruction and
will return to the standby state, when CS is brought high. A new CS falling edge is required to reinitiate the serial
communication.
WC
Block Write Protect Bits
Status Register Bits
, RDSR).
BP1
0
0
1
1
BP0
0
1
0
1
AT25010B
607F
407F
007F
None
Array Addresses Protected
AT25020B
C0FF
80FF
00FF
None
AT25040B
180FF
1001FF
0001FF
None
Table
3-4.
8707B–SEEPR–3/10