at49lw080 ATMEL Corporation, at49lw080 Datasheet - Page 16

no-image

at49lw080

Manufacturer Part Number
at49lw080
Description
8-megabit Firmware Hub Flash Memory
Manufacturer
ATMEL Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
at49lw080-33JC
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
at49lw080-33JC
Manufacturer:
ATMEL
Quantity:
8 000
Part Number:
at49lw080-33JC
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
at49lw080-33JX
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
at49lw080-33JX SL383
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
at49lw080-33TC
Manufacturer:
SST
Quantity:
10 914
Part Number:
at49lw080-33TC
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
at49lw080-33TL
Manufacturer:
NS
Quantity:
1 373
Part Number:
at49lw080-33TL
Manufacturer:
ATMEL
Quantity:
3 524
Part Number:
at49lw080-33TL
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
at49lw080-33TX
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
6.10
6.11
Table 6-8.
16
Bit
7:5
4
3
2
1
0
Lock-down
General-purpose Inputs Register
AT49LW080
General-purpose Input Registers
Function
Reserved
FGPI[4]
Reads status of general-purpose input pin (PLCC-30/TSOP-7)
FGPI[3]
Reads status of general-purpose input pin (PLCC-3/TSOP-15)
FGPI[2]
Reads status of general-purpose input pin (PLCC-4/TSOP-16)
FGPI[1]
Reads status of general-purpose input pin (PLCC-5/TSOP-17)
FGPI[0]
Reads status of general-purpose input pin (PLCC-6/TSOP-18)
When in the FWH interface mode, the default lock-down status of all sectors upon power-up is
not-locked-down (0 state). The lock-down bit for any sector may be set (1 state), but only once,
as future attempted changes to that sector locking register will be ignored. The lock-down bit is
only cleared upon a device reset with RST or INIT. The current lock-down status of a particular
sector can be determined by reading the corresponding lock-down bit. Once a sector’s lock-
down bit is set, the read- and write-lock bits for that sector can no longer be modified and the
sector is locked down in its current state of read and write accessibility.
This register reads the status of the FGPI[4:0] pins on the FWH at power-up. Since this is a
pass-through register, there is no default value as shown in
the GPI pins be in the desired state before FWH4 is brought low for the beginning of the next
bus cycle, and remain in that state until the end of the cycle.
Table
6-5. It is recommended that
1966G–FLASH–3/05

Related parts for at49lw080