adm9240 Analog Devices, Inc., adm9240 Datasheet - Page 19

no-image

adm9240

Manufacturer Part Number
adm9240
Description
Low Cost Microprocessor System Hardware Monitor
Manufacturer
Analog Devices, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
adm9240-1A
Manufacturer:
AD
Quantity:
5 510
Part Number:
adm9240-1A
Manufacturer:
MOT
Quantity:
5 510
Part Number:
adm9240A
Manufacturer:
AD
Quantity:
5 510
Part Number:
adm9240ARN
Manufacturer:
AD
Quantity:
5 510
Part Number:
adm9240ARN
Manufacturer:
LT
Quantity:
5 510
Part Number:
adm9240ARU
Manufacturer:
AD
Quantity:
1 000
Part Number:
adm9240ARU
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
adm9240ARUZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Bit
0
1
2
3
4
5
6
7
Bit
0
1
7
Bit
0
1
2
3
4
5
6
7
Note: Any time the STATUS Register is read out, the conditions (i.e., Register) that are read are automatically reset. In the case of the channel priority indication, if
two or more channels were out of limits, another indication would automatically be generated if it were not handled during the ISR. In the Mask Register, the errant
voltage interrupt may be disabled until the operator has time to clear the errant condition or set the limit higher/lower.
REV. 0
2
3
4
5
6
Name
START
INT_Enable
Reserved
INT_Clear
RESET
Reserved
CI_Reset
Initialization
Name
+2.5 V_Error
V
+3.3 V_Error
+5 V_Error
Temp_Error
Reserved
FAN1_Error
FAN2_Error
Name
+12 V_Error
V
Reserved
Reserved
Chassis_Error
Reserved
Reserved
Reserved
CCP
CCP2
_Error
_Error
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
R/W
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Read Only
Table VIII. Register 41h, Interrupt Status Register 1 (Power-On Default = 00h)
Table IX. Register 42h, Interupt Status Register 2 (Power-On Default = 00h)
Table VII. Register 40h, Configuration Register (Power-On Default = 08h)
Description
Logic 1 enables startup of ADM9240, Logic 0 places it in standby mode. Caution: the out-
puts of the Interrupt pins will not be cleared if the user writes a zero to this location after an
interrupt has occurred (see “INT_Clear” bit). At startup, limit checking functions and scan-
ning begins. Note, all high and low limits should be set into the ADM9240 prior to turning
on this bit. (Power-Up Default = 0.)
Logic 1 enables the INT output. 1 = Enabled 0 = Disabled (Power-Up Default = 0).
Default = 0.
During Interrupt Service Routine (ISR) this bit is asserted Logic 1 to clear INT output
without affecting the contents of the Interrupt Status Register. The device will stop monitor-
ing. It will resume upon clearing of this bit. (Power-Up Default = 1.)
Creates a RESET (Active Low) signal for 20 ms minimum (Power-Up Default = 0).
This bit is cleared once the pulse goes active.
Default = 0.
A “1” outputs a minimum 20 ms active low pulse on the Chassis Intrusion pin. (Power-Up
Default = 0.) (Note: This bit performs the same function as Bit 7 in Register 46h).
Logic 1 restores power-up default values to the Configuration register, Interrupt status regis-
ters, Interrupt Mask Registers, Fan Divisor Register and the Temperature Configuration
Register. This bit automatically clears itself since the power-on default is zero.
Description
A “1” indicates a high or low limit has been exceeded.
A “1” indicates a high or low limit has been exceeded.
A “1” indicates a high or low limit has been exceeded.
A “1” indicates a high or low limit has been exceeded.
A “1” indicates that a temperature interrupt has been set.
Undefined.
A “1” indicates that a fan count limit has been exceeded.
A “1” indicates that a fan count limit has been exceeded.
Description
A “1” indicates a high or low limit has been exceeded.
A “1” indicates a high or low limit has been exceeded.
Undefined.
Undefined.
A “1” indicates chassis intrusion has gone high.
Undefined.
Undefined.
Undefined.
–19–
ADM9240

Related parts for adm9240