lm6059bcw Topway Display, lm6059bcw Datasheet - Page 6

no-image

lm6059bcw

Manufacturer Part Number
lm6059bcw
Description
Lcd Module User Manual
Manufacturer
Topway Display
Datasheet
3.3
3.3.1
Note:
*1. Input signal rise/fall time should be less than 15ns .
*2. CL=100pF
*3.All timing is using 20% and 80% of VDD as the reference.
URL:
Item
System cycle time
Address setup time (A0)
Address hold time (A0)
Control LOW pulse width (/RD)
Control LOW pulse width (/WR)
Control HIGH pulse width (/RD)
Control HIGH pulse width (/WR)
Data setup time
Data hold time
/RD access time (*2)
Output disable time (*2)
www.topwaydisplay.com
www.topwaysz.com
AC Characteristics
6800 Mode System Bus Timing
LCD Module User Manual
Symbol
tewhw
tewlw
tewhr
tacc6
tcyc6
taw6
tewlr
tah6
tdh6
tds6
tch6
MIN.
500
275
275
225
225
10
10
50
10
13
-
Document Name: LM6059BCW-Manual-Rev0.3.DOC
TYP.
-
-
-
-
-
-
-
-
-
-
-
V
SS
=0V, V
MAX.
175
125
-
-
-
-
-
-
-
-
-
DD
=3.0V, T
LM6059BCW
Page: 6 of 13
OP
Unit
Ns
Ns
Ns
Ns
Ns
Ns
ns
ns
ns
ns
ns
=25°C

Related parts for lm6059bcw