3.3.2 Serial Mode Interface
Note:
*1. Input signal rise/fall time should be less than 15ns .
*2. CL=100pF
*3.All timing is using 20% and 80% of VDD as the reference.
URL:
Item
Serial Clock Period
Address setup time (A0)
Address hold time (A0)
SCL “H” pulse width
SCL “L” pulse width
Data setup time
Data hold time
CS-SCL time
CS-SCL time
www.topwaydisplay.com
www.topwaysz.com
LCD Module User Manual
Symbol
tscyc
tshw
tsas
tsah
tsds
tsdh
tcsh
tslw
tcss
MIN.
125
38
25
63
63
38
25
38
75
Document Name: LM6059BCW-Manual-Rev0.3.DOC
TYP.
-
-
-
-
-
-
-
-
-
V
SS
=0V, V
MAX.
-
-
-
-
-
-
-
-
-
DD
=3.0V, T
LM6059BCW
Page: 7 of 13
OP
Unit
Ns
Ns
Ns
Ns
ns
ns
ns
ns
ns
=25°C