adate302-02 Analog Devices, Inc., adate302-02 Datasheet - Page 14

no-image

adate302-02

Manufacturer Part Number
adate302-02
Description
500 Mhz Dual Integrated Dcl With Differential Drive/receive, Level Setting Dacs, And Per Pin Pmu
Manufacturer
Analog Devices, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
adate302-02BBCZ
Manufacturer:
Analog Devices Inc
Quantity:
10 000
Part Number:
adate302-02BSVZ
Manufacturer:
Analog Devices Inc
Quantity:
10 000
ADATE302-02
Parameter
MEASOUT01 DC CHARACTERISTICS
VOLTAGE CLAMPS
SETTLING/SWITCHING TIMES
MEASOUT01 Voltage Range
DC Output Current
MEASOUT01 Pin Output
Output Leakage Current When
Output Short-Circuit Current
Low Clamp Range (VCL)
High Clamp Range (VCH)
Positive Clamp Voltage Droop
Negative Clamp Voltage Droop
Uncalibrated Accuracy
INL
DUTGND Voltage Accuracy
Voltage Force Settling Time to
Voltage Force Settling Time to
Impedance
Tristated
0.1% of Final Value
Range A, 200 pF and
Range B, 200 pF and
Range C, 200 pF and
Range D, 200 pF and
Range E, 200 pF and
1.0% of Final Value
Range A, 200 pF and
Range B, 200 pF and
Range C, 200 pF and
Range D, 200 pF Load
Range D, 2000 pF Load
Range E, 200 pF Load
Range E, 2000 pF Load
2000 pF Load
2000 pF Load
2000 pF Load
2000 pF Load
2000 pF Load
2000 pF Load
2000 pF Load
2000 pF Load
Min
−2.0
−1
−25
−2.0
0.0
−300
−300
−250
−70
Typ
25
+50
−50
±100
±5
±1
15
20
124
1015
3455
8.0
8.0
8.0
8.1
585
8.1
590
Max
+6.0
4
200
+1
+25
+4.0
6.0
+300
+300
+250
+70
Rev. 0 | Page 14 of 52
Unit
V
mA
Ω
μA
mA
V
V
mV
mV
mV
mV
mV
μs
μs
μs
μs
μs
μs
μs
μs
μs
μs
μs
μs
Test
Level
D
D
P
P
P
D
D
P
P
P
P
C
S
S
S
S
S
C
C
C
C
C
C
C
T
B
B
B
B
B
B
B
Conditions/Comments
PMU enabled, FVMV, PE disabled; source resistance: PMU force
6.0 V and load with 0 mA and 4 mA; sink resistance: PMU force
−2.0 V and load with 0 mA and −4 mA; resistance = ∆V/∆I at
MEASOUT01 pin
Tested at −2.0 V and +6.0 V
PMU enabled, FVMV, PE disabled; source: PMU force 6.0 V,
short MEASOUT01 to −2.0 V; sink: PMU force −2.0 V, short
MEASOUT01 to 6.0 V
PMU enabled, FIMI, Range A, PE disabled, PMU clamps
enabled, VCH = 5 V, VCL = −1 V, PMU force 1 mA and 25 mA
into open; ∆V seen at DUTx pin
PMU enabled, FIMI, Range A, PE disabled, PMU clamps
enabled, VCH = 5 V, VCL = −1 V, PMU force −1 mA and −25 mA
into open; ∆V seen at DUTx pin
PMU enabled, FIMI, Range B, PE disabled, PMU damps enabled,
PMU force ±1 mA into open; VCH errors at calibration points of
0 V and 5 V; VCL errors at the calibration points of 0 V and 4 V
PMU enabled, FIMI, Range B, PE disabled, PMU damps enabled,
PMU force ±1 mA into open; after two-point gain/offset
calibration; measured over PMU clamp range
Over ±0.1 V range; measured at end points of PMU clamp
functional range
SCAP = 330 pF, FFCAP = 220 pF
PMU enabled, FV, PE disabled, program PMUDAC steps of
500 mV and 5.0 V; simulation of worst case, 2000 pF load,
PMUDAC step of 5.0 V
PMU enabled, FV, PE disabled, start with PMUDAC
programmed to 0.0 V, program PMUDAC to 500 mV

Related parts for adate302-02