Datasheet
Display example in ICD mode
S5U1C33000C MANUAL
(C COMPILER PACKAGE FOR S1C33 FAMILY) (Ver. 4)
(2) When the [Trace] window is closed
(3) Logging
The following lists the contents of trace information displayed in ICD mode:
Cycle:
Address:
Code:
Unassemble: Disassembled content of the instruction code
Clk:
Method:
File:
Line:
SourceCode: Source code
In ICD mode, the trace information can also be displayed while the program is being executed. By clicking
the [Display trace] button, the S5U1C33000H suspends tracing and displays the sampled trace memory data
to the [Trace] window. The trace operation can be resumed by clicking the [Resume trace] button.
16 lines (default) of trace data are displayed in the [Command] window. The number of display lines can be
changed using the md command.
The latest data is shown on the bottom line of the window if trace cycle No. is omitted. When a trace cycle
No. is specified, data of the specified cycle is shown on the bottom line.
To save the command execution results to a log file, close the [Trace] window and display the results in the
[Command] window. If the [Trace] window is open, the display contents will not be saved in the file
because the [Command] window does not display the results.
[Display trace] button
Trace cycle (decimal)
The last information taken into the trace memory becomes 000000.
CPU-instruction-execution address (hexadecimal)
Instruction code executed by the CPU (hexadecimal)
Number of clocks used for executing the instruction
By default, the cumulative clock count from start of tracing is displayed. It can be changed so
that the number of clocks for each executed instruction is displayed.
Trace analytical method (to get the executed PC address)
Source file name (which includes the executed instruction)
Source line number
SPC:
TRG: Analyzed with the trigger address
DPC:
RET:
MAP: Analyzed with the map information
RTI:
---:
Analyzed with the start PC address
Analyzed with the DPCO signal
Analyzed with the call/ret statement
Analyzed with the reti statement
Cannot be analyzed