lb15-10b24 MORNSUN Science& Technology Ltd., lb15-10b24 Datasheet
lb15-10b24
Related parts for lb15-10b24
lb15-10b24 Summary of contents
Page 1
... LB15-10B12 UL/CE LB15-10B15 UL/CE LB15-10B24 Remarks: 1. Ripple and Noise were measured by the method of parallel lines; 2. Unless otherwise specified, all specifications above are measured at rated input voltage and rated output load, TA=25°C, humidity < 75%; 3. Add suffix “I” for regulated slave output, and build-in line regulator. The slave output can not be continuously shorted, and neither can it be continuously overcurrent. ...
Page 2
... INPUT SPECIFICATIONS Input voltage range Input frequency Input current LB03 models LB05models LB10 models LB15 models Inrush current LB03/05 models LB10/15 models LB03/05 models External input fuse (recommended) LB10/15 models OUTPUT SPECIFICATIONS Voltage set accuracy Input variation Load variation (10%-100%) Single output models ...
Page 3
... N T VS1 RL T VS2 RL EXTERNAL TYPICAL VALUE C3(uF) MODEL LB10-10B03 LB10-10B05 LB10-10B09 LB10-10B12 LB10-10B15 LB10-10B24 LB10-10A05 LB10-10A12 LB10-10A15 LB10-10D0505-02I LB15-10B03 120 LB15-10B05 LB15-10B12 68 47 LB15-10B15 10 LB15-10B24 Load Oscillograph TVS1 TVS2 RL C1(uF) C3(uF) 470 330 120 120 ...
Page 4
... A 48 40.5 D 4.0 16 20.5 H 6.0 FOOTPRINT DETAILS Pin LB**-10B LB**-10A LB**-10C LB**-10D 1 AC( AC( Pin Pin 7 No Pin No Pin 8 Trim Trim* :There Trim*:Only For LB15-10BXXSeries。 MODLES WEIGHT (TYP mpera ture( C) First Angle Projection LB05 LB10 LB15 17.5 17.5 20.0 55.0 62.0 70.0 47.0 54.0 62.0 5.0 5.0 5.75 20.0 20.0 23.0 45.0 45.0 48.0 21.0 22.5 23.5 6.0 6.0 6.0 * ...
Page 5
AC-DC Converter Application Guidelines 1. Foreword The following guidelines should be carefully read prior to converter use. Improper use may result in the risk of electric shock, damaging the converter, or fire. Risk of Injury 1.1 To avoid the risk ...
Page 6
... The application circuit shown in Figure 1 is typical application circuit, whereby all MORNSUN products will meet EMI Class B, and Class 3 lightening strike and surge testing (see component datasheets for more details). To comply with more stringent EMC testing, additional filtering should be incorporated. See Figure 2 for a suggested filtering circuit. ...
Page 7
For multi-output converters, the main output is typically a fully regulated output. If the end application requires critical regulation on the auxiliary output(s), a linear regulator or other regular should be added after the converter. (Note: Some MORNSUN converters have ...
Page 8
Ambient Air Cooling For miniature and high power density converters, free air cooling is recommended, mainly due to cost and space concerns. Heat dissipates to the ambient air through the converter ...
Page 9
The heat sink should be made of a good heat conducting material, such as aluminum and copper. The larger the surface area, the better the radiation. Therefore, heat sinks usually have a ridged surface or special coatings to make a ...
Page 10
Input Voltage vs Load Capability (LD03-00B24 10% 20% 30% 40% Load 0% 10% 20% 30% 85VAC 23.85 23.82 23.79 23.77 80VAC 23.83 23.82 23.82 23.83 75VAC 23.83 23.83 23.83 23.83 70VAC ...