LB15-10B03 MORNSUN [MORNSUN Science& Technology Ltd.], LB15-10B03 Datasheet

no-image

LB15-10B03

Manufacturer Part Number
LB15-10B03
Description
AC-DC CONVERTER
Manufacturer
MORNSUN [MORNSUN Science& Technology Ltd.]
Datasheet
The copyright and authority for the interpretation of the products are reserved by Mornsun
Approval
LBXX-10XXX SERIES
provided by Mornsun. The features of this series are: wide input voltage, DC
and AC all in one, high efficiency, high reliability, low loss, safety isolation etc.
They are widely used in industrial, office and civil equipments. EMC and safety
standards meet international standards IEC61000 UL60950 and IEC60950, and
Multi-certificate is in processing.
PRODUCT FEATURES
1. Universal Input :100 ~ 240VAC,50/60Hz
2. AC and DC all in one (input from the same terminal)
3. Low Ripple and Noise
4. Overload protection and short circuit protection
5. Low loss, green power
6. Multiple models available
7. industrial level specifications
8. 3 years warranty
PRODUCT PROGRAM
UL/CE
UL/CE
UL/CE
UL/CE
UL/CE
UL/CE
UL/CE
UL/CE
UL/CE
UL/CE
UL/CE
UL/CE
UL/CE
UL/CE
UL/CE
UL/CE
UL/CE
UL/CE
UL/CE
UL/CE
UL/CE
UL/CE
UL/CE
UL/CE
Remarks:
1. Ripple and Noise were measured by the method of parallel lines;
2. Unless otherwise specified, all specifications above are measured at rated input voltage and rated output load, TA=25°C, humidity < 75%;
3. Add suffix “I” for regulated slave output, and build-in line regulator. The slave output can not be continuously shorted, and neither can it be continuously overcurrent.
4. All specifications stated in this datasheet are subject to the above listed models only. For specifications of non-standard models, please contact our technical
LB---- are high efficiency green power modules with various packaging
support team.
LB03-10B03
LB03-10B05
LB03-10B12
LB03-10B15
LB03-10B24
LB05-10B03
LB05-10B05
LB05-10B09
LB05-10B12
LB05-10B15
LB05-10B24
LB05-10A05
LB05-10A12
LB05-10A15
LB05-10A24
LB05-10D0505-01
LB05-10D0512-01
LB05-10D0515-01
LB05-10D0524-01
LB10-10B03
LB10-10B05
LB10-10B09
LB10-10B12
LB10-10B15
LB10-10B24
LB10-10A05
LB10-10A12
LB10-10A15
LB10-10D0505-02I
LB15-10B03
LB15-10B05
LB15-10B12
LB15-10B15
LB15-10B24
Model
48.5X36X20.5mm
55X45X21.0mm
62X45X22.5mm
70X48X23.5mm
Package
Power
10W
15W
11W
3W
5W
Output (Vo1/Io1)
3.3V/1000mA
3.3V/1500mA
3.3V/3000mA
3.3V/3500mA
+12V/210mA
+15V/170mA
+24V/100mA
+5V/1000mA
+12V/450mA
+15V/350mA
12V/1250mA
15V/1000mA
12V/250mA
15V/200mA
24V/125mA
5V/1000mA
12V/450mA
15V/350mA
24V/230mA
+5V/500mA
+5V/900mA
+5V/750mA
+5V/700mA
+5V/600mA
5V/2000mA
12V/900mA
15V/700mA
24V/450mA
5V/2000mA
5V/3000mA
24V/625mA
9V/1100mA
5V/600mA
9V/600mA
MODEL SELECTION
Output (Vo2/Io2)
LB10-10B24
+12V/100mA
+15V/100mA
+24V/100mA
-12V/210mA
-15V/170mA
-24V/100mA
-5V/1000mA
-12V/450mA
-15V/350mA
+5V/100mA
-5V/500mA
5V/200mA
Specifications subject to change without notice.
LB**
Noise(Typ.)
Ripple and
Output Voltage
Output Style
In
Isolation Voltage
Rated Power
Package Style
Product Series
50mV
50mV
50mV
50mV
put Voltage
A/1-2008
Efficiency(%)
Page 1 of 4
(Typ.)
68
71
74
75
77
70
73
75
76
78
79
70
74
75
77
70
74
74
75
70
73
77
78
78
80
73
78
79
72
71
74
79
80
81

Related parts for LB15-10B03

LB15-10B03 Summary of contents

Page 1

... LB10-10B03 LB10-10B05 LB10-10B09 LB10-10B12 LB10-10B15 62X45X22.5mm LB10-10B24 LB10-10A05 LB10-10A12 LB10-10A15 LB10-10D0505-02I UL/CE LB15-10B03 UL/CE LB15-10B05 70X48X23.5mm UL/CE LB15-10B12 UL/CE LB15-10B15 UL/CE LB15-10B24 Remarks: 1. Ripple and Noise were measured by the method of parallel lines; 2. Unless otherwise specified, all specifications above are measured at rated input voltage and rated output load, TA=25°C, humidity < 75%; ...

Page 2

... INPUT SPECIFICATIONS Input voltage range Input frequency Input current LB03 models LB05models LB10 models LB15 models Inrush current LB03/05 models LB10/15 models LB03/05 models External input fuse (recommended) LB10/15 models OUTPUT SPECIFICATIONS Voltage set accuracy Input variation Load variation (10%-100%) Single output models ...

Page 3

... C2:0.1μF LB**-10A**(Dual output) F use TVS1 VS1 RL T VS2 RL EXTERNAL TYPICAL VALUE C3(uF) MODEL LB10-10B03 LB10-10B05 LB10-10B09 LB10-10B12 LB10-10B15 LB10-10B24 LB10-10A05 LB10-10A12 LB10-10A15 LB10-10D0505-02I LB15-10B03 120 LB15-10B05 LB15-10B12 68 47 LB15-10B15 10 LB15-10B24 Load Oscillograph TVS1 ...

Page 4

... A 48 40.5 D 4.0 16 20.5 H 6.0 FOOTPRINT DETAILS Pin LB**-10B LB**-10A LB**-10C LB**-10D 1 AC( AC( Pin Pin 7 No Pin No Pin 8 Trim Trim* :There Trim*:Only For LB15-10BXXSeries。 MODLES WEIGHT (TYP mpera ture( C) First Angle Projection LB05 LB10 LB15 17.5 17.5 20.0 55.0 62.0 70.0 47.0 54.0 62.0 5.0 5.0 5.75 20.0 20.0 23.0 45.0 45.0 48.0 21.0 22.5 23.5 6.0 6.0 6.0 * ...

Page 5

AC-DC Converter Application Guidelines 1. Foreword The following guidelines should be carefully read prior to converter use. Improper use may result in the risk of electric shock, damaging the converter, or fire. Risk of Injury 1.1 To avoid the risk ...

Page 6

... The application circuit shown in Figure 1 is typical application circuit, whereby all MORNSUN products will meet EMI Class B, and Class 3 lightening strike and surge testing (see component datasheets for more details). To comply with more stringent EMC testing, additional filtering should be incorporated. See Figure 2 for a suggested filtering circuit. ...

Page 7

For multi-output converters, the main output is typically a fully regulated output. If the end application requires critical regulation on the auxiliary output(s), a linear regulator or other regular should be added after the converter. (Note: Some MORNSUN converters have ...

Page 8

Ambient Air Cooling For miniature and high power density converters, free air cooling is recommended, mainly due to cost and space concerns. Heat dissipates to the ambient air through the converter ...

Page 9

The heat sink should be made of a good heat conducting material, such as aluminum and copper. The larger the surface area, the better the radiation. Therefore, heat sinks usually have a ridged surface or special coatings to make a ...

Page 10

Input Voltage vs Load Capability (LD03-00B24 10% 20% 30% 40% Load 0% 10% 20% 30% 85VAC 23.85 23.82 23.79 23.77 80VAC 23.83 23.82 23.82 23.83 75VAC 23.83 23.83 23.83 23.83 70VAC ...

Related keywords