B37941X1102K060 EPCOS [EPCOS], B37941X1102K060 Datasheet - Page 8

no-image

B37941X1102K060

Manufacturer Part Number
B37941X1102K060
Description
Multilayer ceramic capacitor
Manufacturer
EPCOS [EPCOS]
Datasheet
Specification and stress test methods
KB VS PE
Please read Cautions and warnings and
Important notes at the end of this document.
Multilayer ceramic capacitor
MLSC series
No.
1
3
4
5
6
7
Stress test
Pre- and post-stress electrical test
High temperature exposure
Temperature cycling
Destructive physical analysis
Moisture resistance
Biased humidity
Specification and acceptance criteria
X7R
Initial values in accordance to chapter “Electrical
data”
∆C/C within ±4.5%
∆C/C within ±7.5% for 25 V
D.F. < 25 · 10
D.F. < 50 · 10
I.R. > 1 · 10
(whichever is less)
∆C/C within ±4.5%
∆C/C within ±7.5% for 25 V
D.F. < 25 · 10
D.F. < 50 · 10
I.R. > 1 · 10
(whichever is less)
No defects or abnormalities
∆C/C within ±10%
∆C/C within ±12.5% for 25 V
D.F. < 25 · 10
D.F. < 75 · 10
I.R. > 1 · 10
(whichever is less)
∆C/C within ±10%
∆C/C within ±12.5% for 25 V
D.F. < 25 · 10
D.F. < 75 · 10
I.R. > 1 · 10
(whichever is less)
5
5
3
3
MΩ or τ > 1000 s resp. 500 s for 25 V
MΩ or τ > 1000 s resp. 500 s for 25 V
MΩ or τ > 50 s resp. 25 s for 25 V
MΩ or τ > 50 s resp. 25 s for 25 V
-3
-3
-3
-3
-3
-3
-3
-3
for 25 V
for 25 V
for 25 V
for 25 V
Page 8 of 14
MLSC 0805, 50 V and 100 V
Test description in
accordance to AEC-Q200
Initial and final measurements 24 ±2 h
after test and / or heat treatment (only
X7R dielectrics) @ room temperature
Capacitor fixed on PCB, apply 150 °C
for 1000 ±12 h, measurements 24 ±2 h
after tests @ room temperature
Capacitor fixed on PCB, apply 1000
cycles between -55 °C/150 °C, transfer
time < 10 s, dwell time > 15 min,
measurements 24 ±2 h after heat
treatment (150 °C, 1 h) @ room
temperature
Per EIA-469
Apply the cycle given in MIL-STD-202
Method 106 (25 to 65 °C, 80 to 100%
RH) 10 times, measurements 24 ±2 h
after tests @ room temperature
Apply 85 °C/85% RH and rated voltage
for 1000 ±12 h, surge current < 50 mA,
measurements 24 ±2 h after heat
treatment (150 °C, 1 h) @ room
temperature
B37941X
July 2005

Related parts for B37941X1102K060