BSW841 BEREX [BeRex Corporation], BSW841 Datasheet

no-image

BSW841

Manufacturer Part Number
BSW841
Description
DC~4GHz Wide Band Single Pole Double Throw Switch
Manufacturer
BEREX [BeRex Corporation]
Datasheet
Input Power
Storage Temperature
Operating Temperature
BeRex
SPDT Switch
DC~4GHz Wide Band Single Pole Double Throw Switch
Device Features and Description
43.0dB Typical Isolation at 2GHz
 0.6dB Typical Insertion Loss at 1GHz
 Small Size and Low Profile
 MSOP8 Surface Mount Package
 Lead-free/Green/RoHS compliant
Application
Electrical specifications
All specifications apply with the following test conditions,
Absolute Maximum Ratings
Operation of this device above any of these parameters may result in permanent damage.
(Two-Tone Input Power
Return Loss / Off State
Return Loss / On State
is 5dBm/ Each Tone)
;commercial, space, military wireless system
Switching Speed
1.
2.
3.
Insertion Loss
Parameters
Input P1dB
Input IP3
Isolation
Device performance is measured on BeRex evaluation board at 25˚C, 50 ohm system
Vctl=0/+5Vdc,
DC Blocks are required each port.
Parameters
Frequency
DC-1GHz
DC-2GHz
DC-3GHz
DC-4GHz
DC-1GHz
DC-2GHz
DC-3GHz
DC-4GHz
DC-1GHz
DC-2GHz
DC-3GHz
DC-4GHz
DC-4GHz
0.5-4GHz
0.5-1GHz
0.5-2GHz
0.5-3GHz
0.5-4GHz
0.5-1GHz
0.5-2GHz
0.5-3GHz
0.5-4GHz
Unit
dBm
dBm
dB
dB
dB
dB
ns
Min
50.0/51.5
43.5/45.0
33.0/34.0
27.0/27.5
Typ
26.0
21.0
23.5
16.1
17.0
24.0
23.0
22.0
22.0
47.0
48.0
47.0
46.0
0.6
0.7
0.8
0.9
40
60
-40C to +85C
-55 to +155C
Max
Rating
1W CW
http: //www.berex.com
tRISE, tFALL
(10/90%RF)
tON, tOFF
(50% CTL to 10/90%RF)
Remark
RF1/RF2
BSW841

Related parts for BSW841

BSW841 Summary of contents

Page 1

... Storage Temperature Operating Temperature Operation of this device above any of these parameters may result in permanent damage. Unit Min Typ Max 0.6 0.7 dB 0.8 0.9 50.0/51.5 43.5/45.0 dB 33.0/34.0 27.0/27.5 26.0 21.0 dB 23.5 16.1 dB 17.0 24.0 23.0 dBm 22.0 22.0 47.0 48.0 dBm 47.0 46 Rating 1W CW -55 to +155C -40C to +85C BSW841 Remark RF1/RF2 tRISE, tFALL (10/90%RF) tON, tOFF (50% CTL to 10/90%RF) http: //www.berex.com ...

Page 2

... BeRex Evaluation Board Drawing Insertion Loss vs. Frequency Return Loss vs. Frequency Function Block Diagram Pins 6,7, Bottom Plate must be DC and RF Typical Test Data Isolation vs. Frequency BSW841 grounded. http: //www.berex.com ...

Page 3

... Suggested PCB Land Pattern and PAD Layout Notes : 1. Connection to Bottom Ground with multiple via holes. 2. Via holes as many as possible 3. Dimensions are in inches (millimeters). Visit http://www.berex.com for PCB layout Signal Path State RFC to RF1 + OFF PCB Land Pattern BSW841 RFC to RF2 OFF ON http: //www.berex.com ...

Page 4

... Packaging information: Tape Width (mm): 12 Reel Size (inches): 7 Device Cavity Pitch (mm): 8 Devices Per Reel: 1000EA Class 1C Passes <2000V Human Body Model (HBM) JEDEC Standard JESD22-A114B Level 1 at +265C convection reflow JEDEC Standard J-STD-020 6 F NOTICE BSW841 http: //www.berex.com ...

Related keywords