operaTion
Shutdown State
The LTC4010 remains in micropower shutdown until V
(Pin 15) is driven above BAT (Pin 10). In shutdown all
status and PWM outputs and internally generated supply
voltages are inactive. Current consumption from V
BAT is reduced to a very low level.
Charge Qualification State
Once V
shutdown, enables its own internal supplies and switches
V
cell voltage. The IC also verifies that V
V
1.95V. If V
if V
is described in more detail below. Once adequate voltage
conditions exist for charging, READY is asserted.
If the voltage between V
LTC4010 is paused. If V
2.85V, the LTC4010 verifies that the sensed temperature
is between 5°C and 45°C. If these temperature limits
are not met or if its own die temperature is too high, the
LTC4010 will indicate a fault and not allow charging to
begin. If V
related charge qualification, monitoring and termination
are disabled.
Once charging is fully qualified, precharge begins (unless
the LTC4010 is paused). In that case, the V
monitored for further control. The charge status indicators
and PWM outputs remain inactive until charging begins.
Charge Monitoring
The LTC4010 continues to monitor important voltage and
temperature parameters during all charging states. If V
drops to the BAT voltage or lower, charging stops and the
shutdown state is entered. If V
V
0
CELL
CDIV
CC
CELL
is 510mV above BAT and V
to GND to allow measurement of the average single-
drops below 350mV, charging stops and the LTC4010
CC
is above 1.95V, the fault state is entered, which
is greater than BAT, the LTC4010 exits micropower
CELL
TEMP
is below 350mV, no charging will occur, and
is greater than 2.85V, battery temperature
(Refer to Figure 1)
TEMP
TEMP
and GND is below 200mV, the
is above 200mV but below
CELL
CC
is between 350mV and
drops below 4.25V or
CC
is at or above 4.2V,
TEMP
CC
pin is
and
CC
CC
returns to the charge qualification state. If V
1.95V, charging stops and the IC enters the fault state. If an
external thermistor indicates sensed temperature is beyond
a range of 5°C to 60°C, or the internal die temperature
exceeds a resonable value, charging is suspended, the
charge timer is paused and the LTC4010 indicates a fault
condition. Normal charging resumes from the previous
state when the sensed temperature returns to a satisfactory
range. In addition, other battery faults are detected during
specific charging states as described below.
Precharge State
If the initial voltage on V
enters the precharge state and enables the PWM current
source to trickle charge using one-fifth the programmed
charge current. The CHRG status output is active during
precharge. The precharge state duration is limited to
t
period programmed with the TIMER pin. If sufficient V
voltage cannot be developed in this length of time, the fault
state is entered, otherwise fast charge begins.
Fast Charge State
If adequate average single-cell voltage exists, the LTC4010
enters the fast charge state and begins charging at the
programmed current set by the external current sense
resistor connected between the SENSE and BAT pins.
The CHRG status output is active during fast charge. If
V
processing begins immediately. Otherwise –∆V termination
is disabled for a stabilization period of t
case, the LTC4010 makes another fault check at t
requiring the average cell voltage to be above 1.22V. This
ensures the battery pack is accepting a fast charge. If
V
entered. Fast charge state duration is limited to t
the fault state is entered if this limit is exceeded.
MAX
CELL
CELL
/12 minutes, where t
is initially above 1.325V, voltage-based termination
is not above this voltage threshold, the fault state is
CELL
MAX
is below 900mV, the LTC4010
is the maximum fast charge
MAX
CELL
/12. In that
MAX
exceeds
MAX
CELL
4010fb
/12,
and

Related parts for LTC4010CFEPBF