MOC3041 Motorola, MOC3041 Datasheet - Page 4

no-image

MOC3041

Manufacturer Part Number
MOC3041
Description
6-Pin DIP Zero-Cross Optoisolators Triac Driver Output
Manufacturer
Motorola
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MOC3041
Manufacturer:
MOTOROLA
Quantity:
15 006
Part Number:
MOC3041
Manufacturer:
MOT
Quantity:
287
Part Number:
MOC3041
Manufacturer:
MOT
Quantity:
400
Part Number:
MOC3041
Manufacturer:
FAIRCHILD
Quantity:
2 136
Part Number:
MOC3041
Manufacturer:
FAIRCHILD/仙童
Quantity:
20 000
Part Number:
MOC3041M
Manufacturer:
TI
Quantity:
201
Part Number:
MOC3041M
Manufacturer:
FSC
Quantity:
33 000
Part Number:
MOC3041M
Manufacturer:
FAIRCHILD/仙童
Quantity:
20 000
Part Number:
MOC3041M
0
Company:
Part Number:
MOC3041M
Quantity:
4 500
Company:
Part Number:
MOC3041M
Quantity:
10 000
Part Number:
MOC3041M/CT3041
Manufacturer:
FAIRCHILD/仙童
Quantity:
20 000
Part Number:
MOC3041SD
Manufacturer:
FAIRCHILD/仙童
Quantity:
20 000
Part Number:
MOC3041SR2M
Manufacturer:
FAIRCHILD/仙童
Quantity:
20 000
Company:
Part Number:
MOC3041SR2M
Quantity:
94 000
Company:
Part Number:
MOC3041SR2VM
Quantity:
4 000
* For highly inductive loads (power factor < 0.5), change this value to
MOC3041 MOC3042 MOC3043
V CC
360 ohms.
4
V CC
R in
R in
1
2
3
1
2
3
MOC3041/
3042/
MOC3041/
3043
3042/
3043
330
6
5
4
R1
6
5
4
360
D1
360
Figure 8. Hot–Line Switching Application Circuit
Figure 9. Inverse–Parallel SCR Driver Circuit
39
0.01
LOAD
R2
SCR
HOT
NEUTRAL
240 Vac
D2
SCR
LOAD
In this circuit the “hot” side of the line is switched and the
load connected to the cold or neutral side. The load may be
connected to either the neutral or hot line.
part, 5 mA for the MOC3043, 10 mA for the MOC3042, or
15 mA for the MOC3041. The 39 ohm resistor and 0.01 F
capacitor are for snubbing of the triac and may or may not
be necessary depending upon the particular triac and load
used.
with a Motorola triac driver. Diodes can be 1N4001; resis-
tors, R1 and R2, are optional 330 ohms.
NOTE: This optoisolator should not be used to drive a load directly.
Typical circuit for use when hot line switching is required.
R in is calculated so that I F is equal to the rated I FT of the
Suggested method of firing two, back–to–back SCR’s,
240 Vac
It is intended to be a trigger device only.
Motorola Optoelectronics Device Data