PCA9542 Philips Semiconductors, PCA9542 Datasheet - Page 6

no-image

PCA9542

Manufacturer Part Number
PCA9542
Description
2-channel I2C multiplexer and interrupt controller
Manufacturer
Philips Semiconductors
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PCA9542A
Manufacturer:
PH
Quantity:
20 000
Part Number:
PCA9542AD
Manufacturer:
NXP
Quantity:
3 873
Part Number:
PCA9542AD
Manufacturer:
NXP
Quantity:
182
Company:
Part Number:
PCA9542AD,118
Quantity:
100
Part Number:
PCA9542ADЈ¬118
Manufacturer:
NXP
Quantity:
2 500
Part Number:
PCA9542APW
Manufacturer:
NXP
Quantity:
4 637
Part Number:
PCA9542APW
Manufacturer:
PHI-PB FREE
Quantity:
1 209
Part Number:
PCA9542APW
Manufacturer:
PHILIPS
Quantity:
2 899
Part Number:
PCA9542APW
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Company:
Part Number:
PCA9542APW
Quantity:
453
Part Number:
PCA9542APW/DG118
Manufacturer:
NXP Semiconductors
Quantity:
135
Part Number:
PCA9542APWЈ¬112
Manufacturer:
NXP
Quantity:
3 570
Part Number:
PCA9542PW
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Company:
Part Number:
PCA9542PW
Quantity:
1 912
Philips Semiconductors
Acknowledge
The number of data bytes transferred between the start and the stop conditions from transmitter to receiver is not limited. Each byte of eight bits
is followed by one acknowledge bit. The acknowledge bit is a HIGH level put on the bus by the transmitter whereas the master generates an
extra acknowledge related clock pulse.
A slave receiver which is addressed must generate an acknowledge after the reception of each byte. Also a master must generate an
acknowledge after the reception of each byte that has been clocked out of the slave transmitter. The device that acknowledges has to pull down
the SDA line during the acknowledge clock pulse, so that the SDA line is stable LOW during the HIGH period of the acknowledge related clock
pulse, set-up and hold times must be taken into account.
A master receiver must signal an end of data to the transmitter by not generating an acknowledge on the last byte that has been clocked out of
the slave. In this event, the transmitter must leave the data line HIGH to enable the master to generate a stop condition.
1999 Oct 07
2-channel I
BY TRANSMITTER
1
DATA OUTPUT
Figure 5. Slave address
SDA
SDA
2
SCL
DATA OUTPUT
BY RECEIVER
1
C multiplexer and interrupt controller
fixed
SCL FROM
SDA
MASTER
1
slave address
start condition
S
0
start condition
hardware selectable
S
1
START condition
A2
1
1
X
1
2
A1 A0
SLAVE ADDRESS
S
1
X
1
3
SLAVE ADDRESS
1
X
0
4
Figure 4. Acknowledgement on the I
0
A2
X
5
A2
A1
X
Figure 6. WRITE control register
Figure 7. READ control register
1
6
A1
SW00453
A0
X
7
A0
R/W
X
0
8
R/W
1
A
X
acknowledge
from slave
9
2
A
acknowledge
from slave
X
X
6
1
X
X
X
PREVIOUS CHANNEL
2
CONTROL REGISTER
INT1
X
CONTROL REGISTER
not acknowledge
X
INT1
3
INT0
acknowledge
X
4
INT0
8
X
X
5
2
X
C-bus
B2
X
6
B2
acknowledge
from slave
B1
no acknowledge
from master
X
7
B1
B0
X
9
8
B0
A
last byte
t
pv
9
NA
P
P
stop condition
clock pulse for
acknowledgement
SW00481
NEW CHANNEL
SW00480
Product specification
PCA9542
SW00368

Related parts for PCA9542