M29W320EB NUMONYX [Numonyx B.V], M29W320EB Datasheet - Page 29

no-image

M29W320EB

Manufacturer Part Number
M29W320EB
Description
32 Mbit (4Mbx8 or 2Mbx16, Uniform Parameter Blocks, Boot Block) 3V supply Flash memory
Manufacturer
NUMONYX [Numonyx B.V]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
M29W320EB
Manufacturer:
ST
Quantity:
8 985
Part Number:
M29W320EB
Quantity:
5 000
Part Number:
M29W320EB
Manufacturer:
ST
0
Part Number:
M29W320EB-70
Manufacturer:
ST
0
Part Number:
M29W320EB-70N6
Manufacturer:
ST
Quantity:
8 995
Part Number:
M29W320EB-70N6
Quantity:
13
Part Number:
M29W320EB-70N6
Manufacturer:
NUMONYX
Quantity:
6 707
Part Number:
M29W320EB-70N6
Manufacturer:
ST
0
Part Number:
M29W320EB-70N6
Manufacturer:
MICRON/美光
Quantity:
20 000
Part Number:
M29W320EB-70N6-L
Manufacturer:
ST
0
Part Number:
M29W320EB-70N6E
Manufacturer:
ST
0
M29W320ET, M29W320EB
5
5.1
5.2
Status register
The M29W320E has one Status register. It provides information on the current or previous
Program or Erase operations. The various bits convey information and errors on the
operation. Bus Read operations from any address, always read the Status register during
Program and Erase operations. It is also read during Erase Suspend when an address
within a block being erased is accessed.
The bits in the Status register are summarized in
Data Polling bit (DQ7)
The Data Polling bit can be used to identify whether the Program/Erase Controller has
successfully completed its operation or if it has responded to an Erase Suspend. The Data
Polling bit is output on DQ7 when the Status register is read.
During Program operations the Data Polling bit outputs the complement of the bit being
programmed to DQ7. After successful completion of the Program operation the memory
returns to Read mode and Bus Read operations from the address just programmed output
DQ7, not its complement.
During Erase operations the Data Polling bit outputs ’0’, the complement of the erased state
of DQ7. After successful completion of the Erase operation the memory returns to Read
mode.
In Erase Suspend mode the Data Polling bit will output a ’1’ during a Bus Read operation
within a block being erased. The Data Polling bit will change from a ’0’ to a ’1’ when the
Program/Erase Controller has suspended the Erase operation.
Figure 6: Data Polling
Address is the address being programmed or an address within the block being erased.
Toggle bit (DQ6)
The Toggle bit can be used to identify whether the Program/Erase Controller has
successfully completed its operation or if it has responded to an Erase Suspend. The Toggle
bit is output on DQ6 when the Status register is read.
During Program and Erase operations the Toggle bit changes from ’0’ to ’1’ to ’0’, etc., with
successive Bus Read operations at any address. After successful completion of the
operation the memory returns to Read mode.
During Erase Suspend mode the Toggle bit will output when addressing a cell within a block
being erased. The Toggle bit will stop toggling when the Program/Erase Controller has
suspended the Erase operation.
Figure 7: Toggle
and
Figure 14
describe Toggle bit timing waveform.
flowchart, gives an example of how to use the Data Toggle bit.
flowchart, gives an example of how to use the Data Polling bit. A Valid
Table 7: Status register
bits.
Status register
Figure 13