MC33899VW FREESCALE [Freescale Semiconductor, Inc], MC33899VW Datasheet - Page 21

no-image

MC33899VW

Manufacturer Part Number
MC33899VW
Description
Programmable H-Bridge Power IC
Manufacturer
FREESCALE [Freescale Semiconductor, Inc]
Datasheet
Fault Detection During ON State
side MOSFET is ON), the 33899 is capable of detecting both
shorts to VIGNP and shorts to ground. A short will cause the
appropriate MOSFETs to current limit. The current limit is
active for numerous retry periods until an over-temperature
condition is reached, at which time all outputs are turned
OFF.
exceeds the fault time before the 33899 will consider them
valid. Once they are valid, they are latched until the SPI has
reported these faults to the microcontroller via the DO pin and
a logic [1] is written to the FLTCLR bit.
Analog Integrated Circuit Device Data
Freescale Semiconductor
While the H-Bridge circuit is in operation (i.e., when a high
All ON-state faults must be present for a period of time that
state faults have been reported, a minimum ON time is
required for the low side MOSFET. For example, if the PWM
frequency is 11kHz, ON-state fault detection would not be
guaranteed for duty cycles of less than 11%.
Thermal Shutdown
fault sets the thermal shutdown bits (and any other faults that
may be present at that time) and latches off. The H-Bridge will
remain disabled until the microprocessor sets the FLTCLR bit
(refer to
In order for the user to be certain that all detectable ON-
The H-Bridge has thermal protection circuitry. A thermal
Table
8, page 22).
FUNCTIONAL DEVICE OPERATION
OPERATIONAL MODES
33899
21

Related parts for MC33899VW