MLX90110 Electrical Specifications
Operating Parameters are based on test set up (see Schematic below).
Toper = -40 C to 85 C, Operating frequency = 120kHz (unless otherwise specified)
Parameter
Regulated supply voltage
Power On Level
Sensitivity level
Transponder Modulation Depth
High Programmation voltage
Low Programmation voltage
EEPROM writing supply current
EEPROM data retention
EEPROM write cycles
Coil-GND tune capacitor
DC input current clamping
Notes:
MLX90110 128bit MTP Transponder
Note (1): All specification values are characterized
and tested 100%, or guaranteed by design.
Note (2): All specifications are valid for Manchester
and Biphase encoding, and for 2kbaud and 4kbaud
data rate options.
Note (3): Maximum supply voltage is generated by
forcing 10mA between coil and ground pin.
Note (4): For the test setup, AC generator voltages
are equivalent to following voltages on the coil: see
graph (to be added).
Symbol
VDD
VPOR
Vacsens
Vacprh
Vacprl
Iee
Tret
Ncycle
IclampLow VdutDC = +/- 2V
IclampHigh VdutDC = +/- 10V
Test Conditions
(3)
Continuous normal reading of the ID
Continuous normal reading of the ID
Weak power: Vacmin = 200mVpp
Medium power: Vac = 5Vpp
High power: Vac = 20Vpp
Critical reading ID
Critical reading ID
Toper=25
o
C
Page 2 of 10
Vin
Vac
128bit OTP/RW Transponder
Qrc @ 120KHz=48.8
Cpar=10pF
C1+C2=250pF
L=6.8mH
Min
100k
1.55
200
3.0
0.3
2.8
10
77
5
5
1
Typ
MLX90110
170
1.8
3.5
10
80
40
Vdut
Rev 1.14 1-Dec-2000
Max
C1
1000 nA
4.0
2.2
7.5
2.5
10
83
10
4
COIL
GND
Units
V
V
mV (4)
V
V
V
V (4)
V (4)
year
cycles
pF
mA
A
C2