Datasheet
The MLX90609 can simultaneously output analog and digital signals.
The analog output signal can be fed to a microcontroller (µC) that contains an analog-to-digital
converter. A multiplexer can be used to select between the temperature and the angular rate
signals. The MLX90609 generates an internal reference voltage used for supplying the ADC,
thereby maintaining accuracy regardless of the supply voltage of the µC.
Whilst supplying the analog output signal, the MLX90609 can simultaneously send a digital output
signal to the µC through the SPI.
Notes:
1.
2.
3.
390109060901
Rev 008
6. Applications Examples
The bandwidth of the MLX90609 can be selected by connecting an appropriate capacitor in
the FLT pin. C
SC filter. The –3dB bandwidth set by C
It is recommended to use C
switching spikes at the output.
It is recommended to use X5R or X7R type capacitors. Min. voltage for C
more, and 10V or more for the other capacitors. Recommended values of decoupling
capacitors C
as possible to their respective pins.
HVIN is a high impedance node. Be sure that an equivalent leakage resistance at this node
isn’t less then 2M
1
Figure 6-1. MLX90609 with
and C
FLT
implements a first order low pass filter cascaded with an internal 4-th order
2
are 1.0µF and 0.1µF for C
FLT
even if the cut-off frequency is not specified to reduce
Page 15 of 22
simultaneous analog and digital output
FLT
Angular Rate Sensor (Standard version)
is: f
OUT
3
. These capacitors should be placed as close
=0.16 / (R
MLX90609
OUT
*C
FLT
), with R
3
OUT
should be 25V or
= 200k (typ).
Data Sheet
February/08