7.57
Destructive read Address 00111
Reset value: 0000
scri
Note: A synchronization error (scri) generates a random number of parity errors (per)
Data Sheet
15
7
ICRC Synchronization Errors at Clock Recovery Interface (scri)
Synchronization Error at the Clock Recovery Interface
This field counts the amount of synchronization errors at the internal
clock recovery interface. In case there are more than 255 errors, the
value is kept
H
H
not used
scri[7:0]