HCPL-2300-060 HP [Agilent(Hewlett-Packard)], HCPL-2300-060 Datasheet - Page 7

no-image

HCPL-2300-060

Manufacturer Part Number
HCPL-2300-060
Description
8 MBd Low Input Current Optocoupler
Manufacturer
HP [Agilent(Hewlett-Packard)]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HCPL-2300-060E
Manufacturer:
AVAGO/安华高
Quantity:
20 000
Package Characteristics
For -40°C ≤ T
*The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output
continuous voltage rating. For the continuous voltage rating refer to the IEC/EN/DIN EN 60747-5-2 Insulation Characteristics Table
(if applicable), your equipment level safety specification, or Agilent Application Note 1074, “Optocoupler Input-Output Endurance
Voltage.”
Figure 2. Typical Input Diode
Forward Characteristics.
Notes:
1. Bypassing the power supply line is
2. Peaking circuits may produce transient
Input-Output Momentary
Withstand Voltage*
Resistance, Input-Output
Capacitance, Input-Output
required with a 0.1 µF ceramic disc
capacitor adjacent to each optocoupler
as illustrated in Figure 19. The power
supply bus for the optocoupler(s)
should be separate from the bus for
any active loads, otherwise a larger
value of bypass capacitor (up to
0.5 µF) may be needed to suppress
regenerative feedback via the power
supply.
input currents up to 100 mA, 500 ns
maximum pulse width, provided
average current does not exceed 5 mA.
Parameter
A
≤ 85°C, unless otherwise specified. All typicals at T
Symbol Min.
V
R
C
ISO
I-O
I-O
3. Device considered a two terminal
4. The t
5. The t
6. CM
Figure 3. Typical Output Voltage vs.
Forward Input Current vs.
Temperature.
3750
device: pins 1, 2, 3, and 4 shorted
together, and pins 5, 6, 7, and 8
shorted together.
measured from the 50% point on the
trailing edge of the input pulse to the
1.5 V point on the trailing edge of the
output pulse.
measured from the 50% point on the
leading edge of the input pulse to the
1.5 V point on the leading edge of the
output pulse.
rise of the common mode voltage to
assure that the output will remain in a
high logic state (i.e., V
H
PLH
PHL
is the maximum tolerable rate of
propagation delay is
propagation delay is
Typ.
10
0.6
12
Max. Units
OUT
> 2.0 V).
V rms
pF
A
= 25°C.
RH ≤ 50%, t = 1 min,
T
V
f = 1 MHz
A
I-O
Test Conditions
= 25°C
= 500 V
7. CM
8. C
9. In accordance with UL 1577, each
Figure 4. Typical Logic High Output
Current vs. Temperature.
7
fall of the common mode voltage to
assure that the output will remain in a
low logic state (i.e., V
test circuit in Figure 8.
optocoupler is momentary withstand
proof tested by applying an insulation
test voltage ≥ 4500 Vrms for 1 second
(leakage detection current limit,
I
before the 100% production test for
partial discharge (Method b) shown in
the IEC/EN/DIN EN 60747-5-2
Insulation Characteristics Table, if
applicable.
I-O
P
is the peaking capacitance. Refer to
L
≤ 5 µA). This test is performed
is the maximum tolerable rate of
OUT
Fig. Notes
< 0.8 V).
3, 9
3
3

Related parts for HCPL-2300-060