IS42S83200B ISSI [Integrated Silicon Solution, Inc], IS42S83200B Datasheet - Page 13

no-image

IS42S83200B

Manufacturer Part Number
IS42S83200B
Description
32Meg x 8, 16Meg x16 256-MBIT SYNCHRONOUS DRAM
Manufacturer
ISSI [Integrated Silicon Solution, Inc]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
IS42S83200B-6TL
Manufacturer:
ISSI
Quantity:
2 148
Part Number:
IS42S83200B-6TLI
Manufacturer:
ISSI
Quantity:
2 148
Part Number:
IS42S83200B-7TL
Manufacturer:
TI
Quantity:
4 592
Part Number:
IS42S83200B-7TL
Manufacturer:
ISSI
Quantity:
135
Part Number:
IS42S83200B-7TLI
Manufacturer:
ISSI
Quantity:
2 148
IS42S83200B,
Notes:
1. H : High level, L : low level, X : High or low level (Don’t care).
2. CKE Low to High transition will re-enable CLK and other inputs asynchronously. A minimum setup
3. Power down and Self refresh can be entered only from the both banks idle state.
4. Must be legal command as defined in Operative Command Table.
5. Illegal if t
Integrated Silicon Solution, Inc. — www.issi.com —
PRELIMINARY INFORMATION Rev. 00E
05/25/06
CKE RELATED COMMAND TRUTH TABLE
Current State
Self-Refresh (S.R.)
Self-Refresh Recovery
Power-Down (P.D.)
All Banks Idle
Any state
other than
listed above
time must be satisfied before any command other than EXIT.
XSR
is not satisfied.
Operation
INVALID, CLK (n - 1) would exit S.R.
Self-Refresh Recovery
Self-Refresh Recovery
Illegal
Illegal
Maintain S.R.
Idle After t
Idle After t
Illegal
Illegal
Begin clock suspend next cycle
Begin clock suspend next cycle
Illegal
Illegal
Exit clock suspend next cycle
Maintain clock suspend
INVALID, CLK (n - 1) would exit P.D.
EXIT P.D. --> Idle
Maintain power down mode
Refer to operations in Operative Command Table
Refer to operations in Operative Command Table
Refer to operations in Operative Command Table
Auto-Refresh
Refer to operations in Operative Command Table
Refer to operations in Operative Command Table
Refer to operations in Operative Command Table
Refer to operations in Operative Command Table
Self-Refresh
Refer to operations in Operative Command Table
Power-Down
Refer to operations in Operative Command Table
Begin clock suspend next cycle
Exit clock suspend next cycle
Maintain clock suspend
IS42S16160B
RC
RC
(3)
(3)
(2)
(2)
(2)
(2)
(5)
(5)
(4)
1-800-379-4774
(1)
n-1
H
L
L
L
L
L
H
H
H
H
H
H
H
H
L
L
H
L
L
H
H
H
H
H
H
H
H
H
H
L
H
H
L
L
CKE
n
X
H
H
H
H
H
H
H
H
H
X
H
H
H
H
H
H
X
H
H
L
L
L
L
L
L
L
L
L
L
L
L
L
L
CS
X
H
X
H
H
X
X
X
X
X
H
H
X
X
X
X
X
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
RAS
X
X
H
H
X
X
H
H
X
H
H
X
X
X
X
X
X
H
X
H
X
X
X
X
X
L
L
L
L
L
L
L
L
L
CAS
X
X
H
X
X
X
H
X
X
H
X
X
X
X
X
X
X
X
H
X
X
H
X
X
X
X
X
L
L
L
L
L
L
L
ISSI
WE Address
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
H
X
X
X
H
X
X
X
X
X
L
L
Op - Code
Op - Code
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
13
®