NCP348 ONSEMI [ON Semiconductor], NCP348 Datasheet - Page 4

no-image

NCP348

Manufacturer Part Number
NCP348
Description
Positive Overvoltage Protection Controller with Internal Low R_ON NMOS FET and Status FLAG
Manufacturer
ONSEMI [ON Semiconductor]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
NCP3488DR2G
Manufacturer:
MXIC
Quantity:
21
Company:
Part Number:
NCP3488DR2G
Quantity:
630
Company:
Part Number:
NCP3488DR2G
Quantity:
630
Part Number:
NCP348AEMTTBG
Manufacturer:
ON Semiconductor
Quantity:
1 975
Part Number:
NCP348AEMTTBG
Manufacturer:
ON
Quantity:
8 000
Part Number:
NCP348AEMTTBG
Manufacturer:
ON/安森美
Quantity:
20 000
Company:
Part Number:
NCP348AEMTTBG
Quantity:
946
Company:
Part Number:
NCP348AEMTTBG
Quantity:
2 584
Part Number:
NCP348AEMTTXG
Manufacturer:
ON/安森美
Quantity:
20 000
Part Number:
NCP348AEMUTBG
Manufacturer:
ON Semiconductor
Quantity:
1 450
Part Number:
NCP348AEMUTBG
Manufacturer:
ON/安森美
Quantity:
20 000
Part Number:
NCP348MTTBG
Manufacturer:
ON/安森美
Quantity:
20 000
Part Number:
NCP348MTTXG
Manufacturer:
ON/安森美
Quantity:
20 000
NOTE:
4. Additional UVLO and OVLO thresholds ranging from UVLO and from OVLO can be manufactured. Contact your ON Semiconductor
ELECTRICAL CHARACTERISTICS
unless otherwise noted.)
TIMINGS
Input Voltage Range
Undervoltage Lockout Threshold (Note 4)
Undervoltage Lockout Hysteresis
Overvoltage Lockout Threshold (Note 4)
Overvoltage Lockout Hysteresis
V
Disable Quiescent Current
Supply Quiescent Current
UVLO Supply Current
FLAG Output Low Voltage
FLAG Leakage Current
EN Voltage High
EN Voltage Low
EN Leakage Current
Startup Delay
FLAG Going Up Delay
Output Turn Off Time
Alert Delay
Disable Time
in
representative for availability.
versus V
Electrical parameters are guaranteed by correlation across the full range of temperature.
out
Resistance
Characteristic
(Min/Max limits values (−40°C < T
UVLO
OVLO
FLAG
Symbol
R
Idd
EN
UVLO
OVLO
Vol
Idd
tstart
tstop
DS(on)
tdis
V
Idd
Vih
Vol
ton
toff
http://onsemi.com
uvlo
leak
in
flag
dis
hyst
hyst
leak
NCP348
4
From V
From V
From V
V
V
V
From V
0.4 V (See Figures 4 & 10)
in
Sink 1.0 mA on FLAG pin
0.3 V (See Figures 3 & 7)
1.2 V (See Figures 3 & 9)
0.3 V (See Figures 4 & 8)
Rload connected on V
Rload connected on V
Sink 50 mA on/FLAG pin
in
in
V
Load connected to V
V
Load connected to V
rises up OVLO threshold
From EN > = 1.2 V to
(See Figures 5 & 12)
in
in
increasing from 5.0 V to
increasing from 5.0 V to
No load. EN = 5.0 V
1.2 V < V
No load. EN = Gnd
FLAG level = 5.0 V
EN = 5.0 V or GND
A
8.0 V at 3.0 V/ms
8.0 V at 3.0 V/ms
= 5.0 V, EN = GND,
= 5.0 V, EN = 1.2 V,
in
out
in
Rload = 5.0 W
< +85°C) and V
V
Conditions
in
> OVLO to FLAG < =
V
V
> OVLO to V
IN
out
IN
> UVLO to V
= 0.3 V to FLAG =
> OVLO
= 2.9 V
< 0.3 V
IN
< UVLO
out
in
out
out
out
out
out
= +5.0 V. Typical values are T
< =
=
3.00
6.00
Min
1.2
1.2
20
50
30
30
3.25
Typ
100
170
6.4
6.0
1.0
1.0
1.5
1.0
1.0
50
65
90
70
20
55
50
Max
100
150
120
150
250
100
400
400
A
3.5
6.8
0.4
5.0
5.0
28
20
70
70
= +25°C,
Unit
mW
mV
mV
mV
mV
ms
ms
mA
mA
mA
mA
nA
nA
ms
ms
ms
V
V
V
V
V

Related parts for NCP348