TB6548F_06 TOSHIBA [Toshiba Semiconductor], TB6548F_06 Datasheet - Page 7

no-image

TB6548F_06

Manufacturer Part Number
TB6548F_06
Description
Three-Phase Full-Wave PWM Sensorless Controller for Brushless DC Motors
Manufacturer
TOSHIBA [Toshiba Semiconductor]
Datasheet
Induced voltage
Turn-on signal
(1) Lead angle: 0 degrees
(2) Lead angle: 7.5 degrees
(3) Lead angle: 15 degrees
(4) Lead angle: 30 degrees
Induced voltage
Turn-on signal
(1) Lead angle: 0 degrees
(2) Lead angle: 7.5 degrees
(3) Lead angle: 15 degrees
(4) Lead angle: 30 degrees
6. Lead Angle Control
7. Lap Turn-on Control
started, automatically changes to the lead angle that has been set using LA0 and LA1. However, if both
LA0 and LA1 are set for High, the lead angle is 30 degrees in the starting forcible commutation as well as
in normal commutation.
Mode starts.
longer (shaded area in the below chart) so as to create some overlap when switching turn-on signals. The
lap time varies depending on the lead angle setting.
OUT_UP
OUT_UN
OUT_VP
OUT_VN
OUT_WP
OUT_WN
OUT_UP
OUT_UN
OUT_VP
OUT_VN
OUT_WP
OUT_WN
OUT_UP
OUT_UN
OUT_VP
OUT_VN
OUT_WP
OUT_WN
OUT_UP
OUT_UN
OUT_VP
OUT_VN
OUT_WP
OUT_WN
OUT_UP
OUT_UN
OUT_VP
OUT_VN
OUT_WP
OUT_WN
OUT_UP
OUT_UN
OUT_VP
OUT_VN
OUT_WP
OUT_WN
OUT_UP
OUT_UN
OUT_VP
OUT_VN
OUT_WP
OUT_WN
OUT_UP
OUT_UN
OUT_VP
OUT_VN
OUT_WP
OUT_WN
The lead angle is 0 degrees during the starting forcible commutation and, when normal commutation is
When SEL_LAP = High, the turn-on electrical angle is 120 degrees. When SEL_LAP = Low, Lap Turn-on
In Lap Turn-on Mode, the time between zero-cross point and the 120-degree turn-on timing becomes
30 degrees
22.5 degrees
15 degrees
PWM control
PWM control
PWM control
PWM control
U
U
PWM control
PWM control
7
PWM control
PWM control
PWM control
PWM control
V
V
PWM control
PWM control
PWM control
PWM control
PWM control
PWM control
PWM control
PWM control
W
W
TB6548F/FG
2006-03-02
PWM control
PWM control
PWM control
PWM control

Related parts for TB6548F_06