20 000
FAULT MODE
driving the
fault condition is removed, except for over-current, severe
short-circuit, over-temperature and under-voltage which will
be reset by a new turn-on command (each fault_control
signal to be toggled).
available (and reset) via the SO pin during the first valid SPI
communication.
28
15XS3400
FUNCTIONAL DEVICE OPERATION
OPERATIONAL MODES
The 15XS3400 is in Fault mode when:
• V
• wake-up = 1,
• fail = X,
• fault=1.
This device indicates the faults below as they occur by
• Over-temperature fault,
• Over-current fault,
• Severe short-circuit fault,
• Output(s) shorted to VPWR fault in OFF state,
• Open load fault in OFF state,
• Over-voltage fault (enabled by default),
• Under-voltage fault.
The
Fault information is retained in the SPI fault register and is
PWR
FS
pin will automatically return to logic [1] when the
FS
and V
pin to logic [0] for RST input is pulled up:
DD
are within the normal voltage range,
SPI register without effect on the corresponding output state
(HS[x]) and the
START-UP SEQUENCE
following sequence is provided:
set to logic [1]) with an external reference clock:
function is not guaranteed.
The Open load fault in ON state is only reported through
The 15XS3400 enters in Normal mode after start-up if
•VPWR and VDD power supplies must be above their
•generate wake-up event (wake-up=1) from 0 to 1 on
And, in case of the PWM module is used (PWM_en bit is
•apply PWM clock on IN0 input pin after maximum 200μs
If the correct start-up sequence is not provided, the PWM
under-voltage thresholds,
RSTB. The device switches to Normal mode with SPI
register content is reset (as defined in
Table
after 50μs typical and all SPI registers are set to default
values (set to logic [0]). The UV fault is reported in the
SPI status registers.
(min. 50μs).