LM95233_07 NSC [National Semiconductor], LM95233_07 Datasheet - Page 24

no-image

LM95233_07

Manufacturer Part Number
LM95233_07
Description
Dual Remote Diode and Local Temperature Sensor with SMBus Interface and TruTherm Technology
Manufacturer
NSC [National Semiconductor]
Datasheet
www.national.com
Register Name
1-Shot
Register Name
Common Status Register
2.3.5 1-Shot
2.4 STATUS REGISTERS
2.4.1 Common Status Register
2.4.2 Status 1 Register (Diode Fault)
Status fault bits for open or shorted diode (i.e. Short Fault: D+ shorted to Ground or D-; Open Fault: D+ shorted to V
During fault conditions the temperature reading is 0 °C if unsigned value registers are read or –128.000 °C if signed value registers
are read.
Bit(s)
1–0
Bit(s) Bit Name
7–0
Bit(s)
7
6
5–4
3
2
1
0
-
Bit Name
R1F[1:0]
Bit Name
BUSY
NR
SR4F
SR3F
SR2F
SR1F
Read/
Write
R/W
Read/
Write
RO
RO
RO
RO
RO
RO
RO
Command
Command
(Hex)
(Hex)
Byte
0x0F
Byte
0x02
Description
Remote Channel 1 Filter Enable
Description
Busy bit (device converting)
Not Ready bit (30 ms), indicates power up initialization sequence is in progress
Reserved – will report "0" when read.
Status Register 4 Flag:
1 – indicates that Status Register 4 has at least one bit set
0 – indicates that all of Status Register 4 bits are cleared
Status Register 3 Flag:
1 – indicates that Status Register 3 has at least one bit set
0 – indicates that all of Status Register 3 bits are cleared
Status Register 2 Flag:
1 – indicates that Status Register 2 has at least one bit set
0 – indicates that all of Status Register 2 bits are cleared
Status Register 1 Flag:
1 – indicates that Status Register 1 has at least one bit set
0 – indicates that all of Status Register 1 bits are cleared
Read/
Write
WO
Read/
Read/
Write
Write
WO
RO
Description
Writing to this register activates one conversion for all the enabled channels
if the chip is in standby mode (i.e. standby bit = 1). The actual data written
does not matter and is not stored.
BUSY
D7
D7
R1F[1:0]
24
00
01
10
11
NR
D6
D6
D5
D5
D4
D4
Filter State
disable all digital filtering
enable basic filter
reserved (do not use)
enable enhanced filter
SR4F SR3F
D3
D3
D2
D2
SR2F SR1F
D1
D1
DD
D0
D0
, or floating).
Default
Default
(Hex)
(Hex)
POR
POR
0x00