AT49BV-LV002 ATMEL Corporation, AT49BV-LV002 Datasheet - Page 2

no-image

AT49BV-LV002

Manufacturer Part Number
AT49BV-LV002
Description
2-Megabit (256K x 8) Single 2.7-volt Battery-Voltage Flash Memory
Manufacturer
ATMEL Corporation
Datasheet
AT49BV/LV002N(T) pin 1 for the DIP and PLCC packages
and pin 9 for the TSOP package are don’t connect pins.
To allow for simple in-system reprogrammability, the
AT49BV/LV002(N)(T) does not require high input voltages
for programming. Five-volt-only commands determine the
read and programming operation of the device. Reading
data out of the device is similar to reading from an EPROM;
it has standard CE, OE, and WE inputs to avoid bus con-
tention. Reprogramming the AT49BV/LV002(N)(T) is per-
formed by erasing a block of data and then programming
on a byte by byte basis. The byte programming time is a
fast 50 s. The end of a program cycle can be optionally
detected by the DATA polling feature. Once the end of a
byte program cycle has been detected, a new access for a
read or program can begin. The typical number of program
and erase cycles is in excess of 10,000 cycles.
Block Diagram
2
AT49BV/LV002(N)(T)
ADDRESS
INPUTS
RESET
GND
VCC
WE
OE
CE
Y DECODER
X DECODER
CONTROL
LOGIC
DATA INPUTS/OUTPUTS
AT49BV/LV002(N)
DATA LATCHES
INPUT/OUTPUT
MAIN MEMORY
MAIN MEMORY
(128K BYTES)
BOOT BLOCK
PARAMETER
PARAMETER
(96K BYTES)
(16K BYTES)
(8K BYTES)
(8K BYTES)
PROGRAM
Y-GATING
I/O7 - I/O0
BUFFERS
BLOCK 2
BLOCK 1
BLOCK 2
BLOCK 1
The device is erased by executing the erase command
sequence; the device internally controls the erase opera-
tions. There are two 8K byte parameter block sections and
two main memory blocks.
The device has the capability to protect the data in the boot
block; this feature is enabled by a command sequence.
The 16K-byte boot block section includes a reprogramming
lock out feature to provide data integrity. The boot sector is
designed to contain user secure code, and when the fea-
ture is enabled, the boot sector is protected from being
reprogrammed.
In the AT49BV/LV002N(T), once the boot block program-
ming lockout feature is enabled, the contents of the boot
block are permanent and cannot be changed. In the
AT49BV/LV002(T), once the boot block programming lock-
out feature is enabled, the contents of the boot block can-
not be changed with input voltage levels of 5.5 volts or less.
8
3FFFF
20000
1FFFF
08000
07FFF
06000
05FFF
04000
03FFF
00000
DATA INPUTS/OUTPUTS
AT49BV/LV002(N)T
DATA LATCHES
INPUT/OUTPUT
MAIN MEMORY
MAIN MEMORY
BOOT BLOCK
(128K BYTES)
PARAMETER
PARAMETER
(16K BYTES)
(96K BYTES)
(8K BYTES)
(8K BYTES)
PROGRAM
Y-GATING
I/O7 - I/O0
BUFFERS
BLOCK 1
BLOCK 2
BLOCK 1
BLOCK 2
8
3FFFF
3C000
3BFFF
3A000
39FFF
38000
37FFF
20000
1FFFF
00000